Appendix B - Discrete Gateway Module (DGM) Connection Details

DGM Digital Outputs

The digital outputs function only when power is supplied to pins 27, 68, and 69 and there is a ground connection to pin 70. See Pin References, page 118, for details. The digital output is rated at 0-30 Vdc, and requires an NEC Class 2 power supply connected to pin 27 for supply bank 1, pin 69 for supply bank 2, and pin 68 for supply bank 3. The DGM provides optical isolation as shown in the following illustration.

Pins: 9-20, 28-39

Maximum continuous current output: 350 mA

Type: Sourcing

 

(sourced from customer supply)

 

 

Recommended continuous current: 100 mA

Microcontroller

Discrete Gateway

Customer Automation

D-Sub Pin 51 (Isolated

Logic Supply)

Isolated Logic ICs

D-Sub

Digital Output

Supply Bank 1

Pin 27

 

Optical

 

 

Isolator

Digital

Output 1-8

 

 

 

 

LOAD

Digital Output

D-Sub

Supply Bank 2

Pin 69

 

Digital

24VDC

 

Output 9-16

 

 

LOAD

D-Sub

Digital Output

Supply Bank 3

Pin 68

 

Digital

 

Output 17-24

 

LOAD

24VDC

D-Sub Pin 70

(Isolated Ground)

120

3A2098H

Page 120
Image 120
Graco 3A2098H important safety instructions DGM Digital Outputs