Epic Fitness EPTL09605.0 manual Problem The walking belt slows when walked on

Page 23

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 9.

b. If the walking belt is overtightened, treadmill perfor- mance may decrease and the walking belt may be permanently damaged. Remove the key and UN- PLUG THE POWER CORD. Using the included allen wrench, turn both rear roller bolts counterclockwise 1/4 of a turn. When the walking belt is properly tight- ened, you should be able to lift each edge of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

b

3–4”

Rear Roller Bolts

 

c. If the walking belt still slows when walked on, please see the front cover of this manual.

PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt is off-center, first remove the key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the allen wrench to turn the left rear roller bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the bolt counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b.If the walking belt slips when walked on, first remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller bolts clockwise 1/4 of a turn. When the walking belt is correctly tight- ened, you should be able to lift each edge of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and walk on the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

a

b

23

Image 23 Contents
Mon.-Fri., 6 a.m.-6 p.m. MST QUESTIONS?Model No. EPTL09605.0 Serial No Call TOLL-FREETable of Contents Treadmill Operation Important PrecautionsPage Right Side Before YOU BeginBack Assembly Not overtighten the Nut the Wheel should turn freely Tape PRE-LUBRICATED Walking Belt HOW to Plug in the Power CordTreadmill Operation HOW to Turn on the Power Features of the ConsoleChange the incline of the treadmill as desired HOW to USE the Manual ModeInsert the key into the console Start the walking beltWhen you are finished using the treadmill When you are finished exercising, removeAdjust the incline of the treadmill to the lowest Demo modeSelect a preset program HOW to USE a Preset ProgramFollow your progress with the displays Select a custom program HOW to Create a Custom ProgramHOW to USE a Custom Program Select a heart rate program HOW to USE a Heart Rate ProgramIf heart rate program Optional Chest Pulse Sensor Information MODE/DEMO ModeHOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Fold the Treadmill for Storage HOW to Lower the Treadmill for USE Reed Switch is about 1/8. If necessary, use a Top TroubleshootingProblem The power turns off during use Switch. Make sure that the gap between the MagnetProblem The walking belt slows when walked on Exercise Frequency Exercise GuidelinesExercise Intensity Workout GuidelinesSuggested Stretches Page Key No. Qty. Description R1105AExploded DRAWING-Model No. EPTL09605.0 108 100 101 104 103 102 Icon Health & FITNESS, INC., 1500 S W., LOGAN, UT HOW to Order Replacement PartsLimited Warranty