Cateye CC-TR200DW (V2c) Measurement screen, Starting/Stopping the measurement, Backlight

Page 9

Starting/Stopping the measurement

Initially, the unit starts or stops measurement automatically in sync with the bicycle motion. This is called auto-mode function. “km/h” or “mph” flashes during measurement.

The total distance, maximum speed, and maximum cadence are up- dated independently of stating/stopping measurement.

Auto-mode function

When the auto-mode is turned on (lights up), the unit detects the wheel spinning, and starts/stops measurement automatically. When the auto-mode is turned off (lights off), the unit starts/ stops measurement by using the SSE button.

*For on/off of the auto-mode, see the menu screen “Setting the auto- mode” (page 31).

* When the transmission is stopped and Sensor signal icons , are off (page 14), the main timer may not start due to speed signal not responding.

Press the M1/+ or M2/- button to turn on the sensor signal icons

,.

Backlight

Pressing the LT button illuminates the displays for about 3 seconds.

*Pressing any button while backlight is still on extends the illumination for another 3 seconds.

AT icon

LT

SSE

Measurement screen

 

ENG

Upper and middle display data

1

1 Current speed

 

 

 

 

Displays the current speed.

 

 

Updated every second.

 

2 Cadence

 

Displays the number of pedal rotations per minute.

2

Updated every second.

3

 

 

3 Average speed *1

 

Displays the average speed after the start of measurement.

 

4 Average cadence *2

4

Displays the average cadence after the start of measurement.

 

* The average will not be reflected when you stop pedaling.

Resetting the measurement data

To reset the measurement data (TM, DST, Lap Time, C.D. DST, etc) and the lap data, simultaneously press the SSE button and the M1/+ or M2/- button in the measurement screen.

*Resetting the measurement data saves the data automatically on a file. (page 23)

*The screen will freeze for about 2 seconds after resetting; however, all measurements are operating normally, including the elapsed time.

*The countdown setting (C.D.DST) is returned to the manu set value you set.

*Cannot reset for 5 seconds after pressing the LAP button.

M1/+

SSE

( S i m u l t a -

neously press)

(or)

SSE M2/-

( S i m u l t a - neously press)

 

5

5 Maximum speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Displays the maximum speed after the start of measurement.

 

 

 

 

 

Updated independently of starting/stopping measurement.

 

 

 

 

 

6 Maximum cadence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Displays the maximum cadence after the start of measurement.

 

 

 

 

 

 

6

 

Updated independently of starting/stopping measurement.

 

 

 

 

 

 

*1: When the trip distance (DST) exceeds 10,000 km [mile], or the elapsed time (TM)

Power-saving function

When the computer does not receive any data for 5 minutes, it will

 

enter the power-saving mode, in which only the date/clock is displayed.

 

By pressing any buttons except the AC recovers from the power-

 

saving mode, and the measurement screen appears. You must press

 

a button when the computer is in power saving mode before it will

Power-saving mode

start to measure any data.

ENG-16

 

exceeds 100 hours, [E] appears indicating further measurement is impossible. Clear

the data by resetting (page 16).

*2: This device calculates the average excluding the time when you stop pedaling. This

feature produces actual averages, which are different from those with conventional

models that calculate it for the entire measurement time period.

ENG-17

Image 9
Contents About the manuals IntroductionProper use of the CatEye V2c ContentsAccessories Description of computer and its parts Screen displayComputer How to install the unit on your bicycle Attach the bracket to the stem or handlebarMount the speed sensor and magnet Preparing the computer Remove/install the computerFormatting/Restarting operation Date/Clock setting24h ↔ 12h ENG-10Tire circumference input How to measure the tire circumference LSet the sensor ID Tire circumferenceSelecting speed unit Basic operation of the computerOperation test Functions on the measurement screenPower-saving function Resetting the measurement dataMeasurement screen Starting/Stopping the measurementLower display data Pace functionLap function Countdown distance Target cadence zoneLap time and split time Advance use of the real time lap dataFile view Changing the computer configurationMeasurement data to be recorded in a file Date of creation New OldENG-24 Viewing the lap dataSwitching the file number Setting the clock/dateDeleting files ENG-26Searching the sensor ID Wheel selection and tire circumference↔ B ENG-28Setting the auto-mode Setting the measurement unitSetting the countdown distance Total distance manual entryCDC.ALARM ↔ BUTTOn Setting soundOn ↔ OFF M1/+M2/- or ENG-32Use of the target zone Trouble shootingCadence zone Trouble on displayTrouble on operation Replacing batterySpeed sensor ENG-36Spare accessories MaintenanceSpecifications Standard accessoriesRegistration Limited warrantyYear computer, and speed sensor Not including depletion of batteries