Precor EFX 883, EFX 833 Completing the Console Installation P80, To complete the installation

Page 37

Installing the Console

35

Completing the Console Installation (P80)

Important: To allow enough room to attach the console’s back cover, you must loosen the bracket holding the upper ends of the handlebars in place. If you do not loosen the bracket, the cover may break. Using a ³₁₆-inch hex key, loosen the two socket head cap screws in the bracket by two or three turns each.

Figure 29: Location of screws on handlebar bracket

Before you complete the final installation steps, double-check the connections you have made. Make sure that all cables are fully and securely connected, and that any unneeded cables are tied back properly.

To complete the installation:

1.Feed extra cable back into the neck tube.

2.Tilt the control console backward (toward yourself) until the tab on the top edge of its back plate slides along the top edge of the console mount and the screw holes align properly.

3.Insert the four ⁵₈-inch flat head screws through the holes in the console mount and thread them into the holes in the back plate on the console. Partially tighten the screws using a ⁵₈-inch hex wrench.

4.Line up the two small tabs at the top of the console’s back cover with the slots at the top of the opening in the console case. Insert the tabs into the slots.

5.Insert the remaining tabs on the back cover with the corresponding slots on the console case.

6.Press gently on the edges of the back cover to snap it into place.

7.Using a ³₁₆-inch hex key, fully retighten the two socket head cap screws securing the handlebar bracket.

Image 37
Contents Assembling and Maintaining Elliptical Fitness Crosstrainers Page Page Trademark Note Edition InformationIntellectual Property Notice Safety Precautions Important Safety InstructionsPage Educating Users Product Recycling and Disposal Hazardous Materials and Proper DisposalRegulatory Notices for the Rfid Module Radio Frequency Interference RFIIndustry Canada Federal Communications Commission, PartVoid the user’s authority to operate the equipment Débranchez avant de réparerRegulatory Notices for Cardiovascular Exercise Equipment Safety Approvals for Cardiovascular EquipmentEuropean Applications Cardiovascular Type EquipmentUser’s authority to operate the equipment IEC-320 C13 and C14 plugs Obtaining Service Obtaining Updated DocumentationTable of Contents Commercial Cardiovascular Equipment Limited Warranty Assembling the EFX To prepare the EFX for assemblyHardware Kit not to scale Installation RequirementsFasteners Assembling the EFX To begin assembly Performing the AssemblyIs properly installed Required ToolsRepeat steps 2 through 4 to attach the right upright support EFX cable path Cable connection points inside EFX base To mount the center column support on the frame Lift cover replacementAttachment of center column support To tighten the fasteners properlyTighten the back fasteners on the upright supports Clamp screw location, EFX handlebar bracket To attach the handlebarsHandrail attachment detail To tighten the handlebars completelyOuter handrail caps attachment To attach the water bottle holderUpright support cover attachment right-hand cover shown To attach the upright support coversTo level the unit Leveling the EFXBreaking in the Equipment Threading the Cable Assembly P80 Installing the ConsoleRemoving the access cover from the P80 console To thread the cable assemblyLocation Connecting Cables P80Cable Connector Type Circuit Location Connecting the Television CableTo connect the television cable Connecting the television cable Connecting the Ethernet and Base Unit Data CablesConnecting the Power Cable Connecting the Heart Rate Sensor CableTo complete the installation Completing the Console Installation P80Threading the Cable Assembly P30 Connecting Cables P30 Verifying That the Heart Rate Display Is Operational Completing the Console Installation P30To verify that the heart rate display is operational Daily Cleaning MaintenanceDaily Inspection Monthly Maintenance Weekly MaintenanceMoving the Equipment Storing the Chest StrapLong-Term Storage Minimum requirements for operation Self-Powered FeaturesRate of Motion Informational Displays Prior to Shutdown Symptoms of a Low BatteryOptional Power Adapter Kit Using the Optional Power AdapterReplacing the Battery Limited Warranty Commercial Cardiovascular Equipment Limited WarrantyWarranty Periods and Coverage Conditions and Restrictions Exclusive Remedies Complete this portion and keep for your records Exclusion of Consequential and Incidental DamagesCommercial Cardiovascular Equipment Limited Warranty Page Page Precor Incorporated Operating and Maintaining the P30 Console Page Page Edition Information Important Safety Instructions Operating and Maintaining the P30 Console  Do not lean on or pull on the console at any time Hazardous Materials and Proper Disposal Regulatory Notices for Cardiovascular Exercise Equipment 240 V Equipment Designated for U.S. Markets 240-volt, 20-amp power plug 120-volt, 20-amp power plugOperating and Maintaining the P30 Console 240 V Equipment Designated Operating and Maintaining the P30 Console Activating the Console for Self-Powered Equipment Activating the Console for Self-Powered EquipmentGetting Started Optional Use of the Power Adapter Identifying Parts of the Console Number Part Name Details Watts Number Part Name Details System Settings Setting Up the ConsoleNavigational keys for the system setting modes Key To view the Club Parameters settings5 1 5 6 Safety Code Treadmill only Setting Club Parameter ValuesSelect Language All Equipment Set Units All EquipmentSet Max Pause Time All Equipment Set Max Workout Time All EquipmentSet Cool Down Time All Equipment Value Range on or OFF Creating a Custom WorkoutTo create a custom program Custom Program keys Equipment Key Name DescriptionSet Incline Limit Treadmill only Set Speed Limit Treadmill onlyHidden Programs Treadmill only Set Crossramp Auto Level EFX Dual only Set Resistance Range Bike onlyValue Range 0 to Viewing the Informational Displays To view the System settingsInformational Displays values Value Information providedProduct Value Information provided Event LogEvent Description of Event Number User ID Entry with Csafe Equipment Csafe access keys Keys FunctionOperating and Maintaining the P30 Console Introducing Users to the P30 Console Using the Touch Heart Rate FeatureHeart rate target zones To use a chest strap transmitter Using a Chest Strap TransmitterInterfere with pacemakers or other Heart rate strapRestart switch Using the Treadmill Safety ClipAttaching the safety clip Treadmill Auto Stop Automatic Stop Function WORKOUT, Press QUICKSTART, or Enter to Begin Starting a WorkoutSetting Options Starting a Preset Programmed WorkoutTo choose a language setting before you begin exercising To choose a workout goal before you begin exercisingTo enter your Age and Weight during a workout Setting Options after You Begin a WorkoutTo choose a unit of measure before you begin exercising Paused Externally Powered Equipment Pausing and Resuming an Exercise SessionPending Shutdown Self-Powered Equipment Ending a Session Operating and Maintaining the P30 Console Manual ProgramsHeart Rate IntervalVariety Weight LossPerformance To remove dust and dirt from the console Cleaning the Console and Display20031 142nd Avenue NE January Box Woodinville, WA USA