ProForm PFTL49390 user manual Trouble-Shooting, Symptom the Power does not Turn on, Top

Page 12

TROUBLE-SHOOTING

Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please call our Customer Service Department toll- free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays).

1.SYMPTOM: THE POWER DOES NOT TURN ON

a.Make sure that the power cord is plugged into a surge protector, and that the surge protector is plugged into a properly grounded outlet. (See HOW TO PLUG IN THE POWER CORD on page 7.) Use only a UL-listed surge protector, rated at 15 amps, with a 14-gauge cord of five feet or less in length.

b.After the power cord has been plugged in, make sure that the key is fully inserted into the console. See step 1 on page 9.

c. Check the circuit breaker located on the treadmill near the power cord. If the switch protrudes as shown, the circuit breaker has tripped. To reset the circuit breaker, wait for five minutes and then press the switch back in.

2. SYMPTOM: THE POWER TURNS OFF DURING USE

c

Tripped

Reset

a. Check the circuit breaker located on the treadmill frame near the power cord (see 1. c. above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b. Make sure that the power cord is plugged in.

c. Remove the key from the console. Reinsert the key fully into the console. See step 1 on page 9.

d.If the treadmill still will not run, please call our Customer Service Department, toll-free.

3.SYMPTOM: THE DISPLAYS OF THE CONSOLE DO NOT FUNCTION PROPERLY

a.Check the batteries in the console. See BATTERY INSTALLATION on page 8. Most problems are the result of drained batteries.

b. Remove the key from the console and UNPLUG THE POWER CORD. Remove the screws from the hood. Carefully remove the hood. Locate the Reed Switch (44) and the Magnet (45) on the left side of the Pulley (50). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Magnet and the Reed Switch is about 1/8Ó. If necessary, loosen the Screw (33) and move the Reed Switch slightly. Retighten the Screw. Re-attach the hood, and run the treadmill for a few minutes to check for a correct speed reading.

44

1/8Ó

50

 

 

 

 

 

45

33

 

 

Top

 

 

View

 

 

12

Image 12 Contents
QUESTIONS? Model No. PFTL49390 Serial NoCustomer HOT Line Table of Contents Important PrecautionsPage Before YOU Begin Right SideBack Assembly Your own phillips screwdriverPage Operation and Adjustment HOW to Plug in the Power CordPerformant Lubetm Walking Belt Console Diagram Battery Installation STEP-BY-STEP Console Operation Insert the key fully into the power switch Reset the speed controlAdjust the incline of the treadmill as desired Start the walking beltHOW to Fold and Move the Treadmill HOW to Fold the Treadmill for StorageHOW to Move the Treadmill SurfaceHOW to Lower the Treadmill for USE TROUBLE-SHOOTING Symptom the Power does not Turn onSymptom the Power Turns OFF During USE TopSymptom the Walking Belt Slows When Walked on Symptom the Walking Belt is OFF-CENTERHOW to Measure Your Heart Rate Conditioning GuidelinesExercise Intensity Workout GuidelinesSuggested Stretches Part LISTÑModel No. PFTL49390 Key No. Qty DescriptionExploded Ordering Replacement Parts Limited WarrantyIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT