TROUBLESHOOTING

Most treadmill problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our toll-free HELPLINE at 1-800-736-6879, Monday through Saturday, 7 a.m. until 7 p.m. Central Time (excluding holidays).

PROBLEM: The power does not turn on

SOLUTION: a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppressor is plugged into a properly grounded outlet (see page 7). Use only a single-outlet surge suppressor that meets all of the specifications described on page 7. Important: The treadmill is not compatible

with GFCI-equipped outlets.

b. After the power cord has been plugged in, make sure that the key is fully inserted into the console.

c. Check the circuit breaker located on the treadmill frame near the power cord. If the switch protrudes as shown, the circuit breaker has tripped. To reset the circuit breaker, wait for five minutes and then press the switch back in.

c

Tripped

Reset

PROBLEM: The power turns off during use

SOLUTION: a. Check the circuit breaker located on the treadmill frame near the power cord (see the drawing

above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b. Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five minutes, and then plug it back in.

c.Remove the key from the console. Reinsert the key fully into the console.

d.If the treadmill still will not run, please call our toll-free HELPLINE.

PROBLEM: The displays of the console do not function properly

SOLUTION: a. Check the batteries in the console. If the batteries need to be replaced, see BATTERY INSTALLATION on page 8. Most problems are the result of drained batteries.

b. Remove the key from the console and

UNPLUG THE

POWER CORD.

Remove the Resistance Knob (98)

from the

left Upright. Remove the screws from the

hood, and carefully remove the hood.

Locate the Reed Switch (86) and the Magnet (87) on

the left side of the Pulley (85). Turn the Pulley until the

Magnet is aligned with the Reed Switch. Make sure that the gap between the Magnet and the Reed

Switch is about 1/8”. If necessary, loosen the Screw

(82)and move the Reed Switch slightly. Retighten the Screw. Re-attach the hood, and run the treadmill for a few minutes to check for a correct speed reading. Reattach the Resistance Knob.

b

 

 

 

 

98

86

1/8

85

 

 

 

 

 

87

82

 

 

Top

 

 

View

 

 

12

Image 12
Contents Model No Serial No Serial Number DecalSEARS, Roebuck and CO Hoffman ESTATES, IL Table of Contents Important PrecautionsNever leave the treadmill unattended while Not in useMove the Treadmill on Before YOU Begin For your benefit, read this manual carefully beforeBack Assembly Assembly requires two peopleExtension Leg with an Extension Leg Screw Into the corresponding connector in the Console Base Other connector in the Console BasePlastic tie tight and cut off the end Until they are snug do not overtighten the ScrewsHOW to Plug in the Power Cord Performant LubeThis product must be grounded.If it should malfunc Grounded Outlet BoxConsole Diagram Adjust the speed in small incrementsBattery Installation 14 for more informationReset position before the walking belt can be restarted Adjust the incline of the treadmill as desiredHOW to USE the Upper Body Arms HOW to Fold the Treadmill for StorageTreadmill, make sure to lift with your legs rather HOW to Move the Treadmill HOW to Lower the Treadmill for USEYour legs and keep your back straight Base Front WheelsTroubleshooting Problem The power does not turn onProblem The power turns off during use Remove the key from the consolePower Cord SolutionProblem ONE of the Upper Body Arms Squeaks During USE HOW to Measure Your Heart Rate Conditioning GuidelinesExercise Intensity Workout GuidelinesExercise Frequency Suggested StretchesFull 90 DAY Warranty SEARS, Roebuck and CO., Dept WA, Hoffman ESTATES, ILRemove this Exploded Drawing and Part List from the Manual Part LIST-Model No Qty Description Key No. QtyR0502A