MAINTENANCE AND TROUBLESHOOTING

Inspect and properly tighten all parts of the exercise cycle regularly. The exercise cycle can be cleaned with a soft, damp cloth. To prevent damage to the console, keep liquids away from the console and keep the console out of direct sunlight.

TIGHTENING THE PEDALS

For best performance, regularly tighten both pedals.

CONSOLE TROUBLESHOOTING

If the console displays flicker or darken, increase your pedaling pace. If the console does not display your heart rate when you use the handgrip pulse sensor, see step 5 on page 12.

HOW TO ADJUST THE REED SWITCH

If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, remove the indicated M4 x 48mm Screws (20) and M4 x 16mm Screws (21) from the Left Side Shield (4). Using an adjustable wrench, turn the Left Pedal (40) clockwise and remove it. Turn the left arm of the Crank (19) so that it is pointing toward the front of the exercise cycle, and then slide off the Left Side Shield.

19

4

 

20

5

 

40

20

Locate the

 

 

Reed Switch

 

 

(44). Turn the

 

 

left arm of the

 

 

Crank (19)

74

21

until the

 

 

 

Magnet (74) is

 

 

aligned with

 

 

the Reed

 

44

Switch.

 

 

Loosen, but

 

19

do not

 

 

 

remove, the

 

 

indicated M4 x 16mm Screw (21). Slide the Reed Switch slightly closer to or away from the Magnet. Then, retighten the Screw. Turn the Crank for a moment. Repeat until the console displays correct feedback. When the Reed Switch is correctly adjust- ed, reattach the left side shield and the left pedal.

HOW TO ADJUST THE DRIVE BELT

If you can feel the pedals slip while you are pedaling, even when the resistance is at the highest level, the Drive Belt (68) may need to be adjusted. Refer to HOW TO ADJUST THE REED SWITCH at the left. To adjust the Drive Belt, the Right Side Shield (5) must first be removed. Remove the indicated M4 x 48mm Screws (20) from the Left Side Shield (4) and the M4 x 16mm Screws (not shown) from the Right Side Shield. Using an adjustable wrench, turn the Right Pedal (not shown) counterclockwise and remove it. Next, turn the right arm of the Crank (not shown) so that it is pointing toward the front of the exercise cycle, and then slide off the Right Side Shield.

21

Next, turn the indicated M8 Nylon Locknut

(56)until the Drive Belt (68) is properly tightened. Then, reattach the right side shield and the right pedal.

68

56

19

Image 19
Contents Model No. PFEX35430 Serial No QUESTIONS?Customer HOT Line Table of Contents Important Precautions Right Side Before YOU BeginBack Assembly Page Page Page HOW to Adjust the Position of the Seat HOW to USE the Exercise CycleHOW to Adjust the Pedal Straps Features of the Console Console DiagramLeft display HOW to USE the Manual ModeBegin pedaling and change the resistance Pedals as desired Monitor your progress with the matrix Two displays MatrixPage Monitor your progress with the two displays HOW to USE a Workout ProgramBegin pedaling to activate the console Select one of the workout programsAudio Cable HOW to Connect Your Portable StereoHOW to Connect Your Home Stereo HOW to Connect Your Computer HOW to Connect Your VCR PressVCR. the play button on your CD player or Follow the on-line instructions to start Program HOW to USE Programs Directly from OUR WEB SiteReturn to the exercise cycle and begin Pedaling HOW to Adjust the Drive Belt Maintenance and TroubleshootingConsole Troubleshooting HOW to Adjust the Reed SwitchExercise Frequency Conditioning GuidelinesExercise Intensity Workout GuidelinesSuggested Stretches Key No. Qty Description Drawing Limited Warranty HOW to Order Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT