Dimension One Spas 2003 manual Glossary of Terms, Aquatic Fitness System is heating

Page 36

Aquatic Fitness System

2003 Owner’s Manual

Glossary of Terms

 

 

 

 

 

Term

 

Definition

 

Air Relief Valve

 

Used for purging air from the filter system whenever servicing the

 

 

 

filter, during initial startup, and whenever you drain and fill the

 

 

 

Aquatic Fitness System.

 

Air Volume Controls

 

Increase or decrease the amount of air drawn through the jets. The

 

 

 

intensity of jet action is varied by adjusting the amount of air mixed

 

 

 

with the water forced through the jets. More air produces a more

 

 

 

vigorous massage. Since air bubbles tend to cool the Aquatic

 

 

 

Fitness System, the air controls should be closed while the

 

 

 

Aquatic Fitness System is heating.

 

Bleeder Valve

 

A small valve used to relieve or expel air from the Aquatic Fitness

 

 

 

System’s plumbing or pump.

 

Circulation Pump

 

A pump that circulates the water in the Aquatic Fitness System

 

 

 

continuously.

 

Diverter Valve

 

Allows you to select either the therapy jets or swim jets with pump

 

 

 

number 1. Simply turn the valve to the desired position.

 

Dry Firing

 

Turning the heater element on when there is no water in the

 

 

 

heater.

 

Equipment Access Panel

 

Provides access to your Aquatic Fitness System’s equipment for

 

 

 

a qualified service technician.

 

Equipment Control System

 

The electronic control system that governs all of the electrically

 

 

 

operated components of your Aquatic Fitness System utilizes an

 

 

 

advanced microprocessor and solid-state electronic switches to

 

 

 

activate all user and maintenance options.

 

Filter Cartridge

 

Your Aquatic Fitness System’s filters have been designed so that

 

 

 

you may repeatedly clean and maintain the filter cartridge as needed.

 

 

 

The cartridge is constructed of woven polyester rather than paper

 

 

 

to ensure long life and proper filtration.

 

Filter Housing

 

The filter canister that houses the filter cartridge. It encloses your

 

 

 

Aquatic Fitness System’s cartridge filter element. This filter

 

 

 

cartridge removes dirt, oil and fine particles from your Aquatic

 

 

 

Fitness System’s water. The lock ring holding the filter cover in

 

 

 

place and the air relief valve in the filter cover must be on and

 

 

 

closed when the Aquatic Fitness System is running. DO NOT

 

 

 

OVER-TIGHTEN THE LOCK RING OR THE AIR RELIEF VALVE.

 

 

 

Also do not open filter housing while the Aquatic Fitness System

 

 

 

is running as the filter is under pressure.

 

Gfci-Ground Fault Circuit

 

A type of Circuit Breaker that automatically disconnects power to

 

Interrupter

 

the Aquatic Fitness System when there is an electrical power

 

 

 

leakage to ground.

 

Gravity Drain Valve

 

Used to drain your Aquatic Fitness System.

 

Halogens

 

Free chlorine, bromine or iodine ions that are very strong oxidizers

 

 

 

used to sanitize water.

32

Image 36
Contents Page Aquatic Fitness System Table of Contents Draining Your Aquatic Fitness System Important Safety Instructions Read and Follow ALL Instructions CarefullyFollowing strenuous exercise Aquatic Fitness System Hyperthermia Do’s Don’tsDimension One Spas, Inc Aquatic Fitness System Features HydroTherapy JetsSwim Jets HydroSport Aquatic Fitness GearRowing Seat Swim Tether MountsBuilt-in OptiMounts Multiple Training StationsAquatic Fitness System Equipment Pack Using Your Aquatic Fitness System Using The Top Side ControlBefore you Start Temperature Set Buttons Jets 1 ButtonJets 2 and Jets 3 Buttons Light ButtonLED Display Window Programming the Filtration Cycle FiltrationStandard Mode Filter CyclesEconomy Mode Lockout Mode Temperature display flashes in this functionAdditional Features Following features are included on your hot tubSpa Included Heater and Circulation Pump ControlOperation of the Spa LED Digital Display Window Jets ButtonAquaFit Dual Temp Up and Down Buttons Program Button Program the Filter Cycle Start Time by pressingProgram the Filter Cycle Duration by pressing the Program Temperature Unit Heat Indicator LightHeat Indicator Light Dimension One Spas Icon Logo ButtonDigital Display Messages OH Overheat ProtectionFlashing LED on the Control Panel Flashing Temperature on Do not Enter the Water if you see a flashingDisplay Routine Equipment Maintenance Filter CleaningDraining Your Aquatic Fitness System SPA AquaFit Dual Temp OnlyLight Bulb Replacement Dimension One EnviroTect Skirts and Vinyl Covers Surface Care ShellCare for the Wood Spa Cabinet Procedure for Winterizing Special Cold Weather InstructionsItems Required for Winterizing Aquatic Fitness System Replace all equipment access panels onto the system Spring Time StartupWarranty Service Information Do not block the air intakesGlossary of Terms Aquatic Fitness System is heatingUsed to drain your Aquatic Fitness System Light Skimmer Door Aquatic Fitness System side control panelTroubleshooting Guide Heating SystemElectrical System Water SystemSelf-Diagnostic Control System AquaFit, AquaFitDual Temp Pool-Side, AquaProHigh temperature condition AquaFitDual Temp Spa-SideTemperature Probe Failure Call the dealer for service