AquaFit™, AquaFit™Dual Temp (Pool-Side), AquaPro™

 

 

 

 

 

 

 

 

 

Symptom

 

Problem

 

 

Corrective Action

 

 

 

 

Non-functional

 

 

Call your dealer for service.

 

 

 

 

High Temperature Sensor:

 

 

 

 

 

 

 

Open high temperature sensor. Heater is

 

 

 

 

 

 

 

deactivated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-functional temperature sensor:

 

 

Call your dealer for service.

 

 

 

 

Open temperature sensor. Heater is

 

 

 

 

 

 

 

deactivated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Flow Problem:

 

 

Call the dealer for service.

 

 

 

 

Pressure switch is not closed when the

 

 

 

 

 

 

 

pump is activated. Heater is deactivated.

 

 

 

 

 

 

 

Proper flow of water is inhibited or

 

 

 

 

 

 

 

pressure switch has malfunctioned. Check

 

 

 

 

 

 

 

for proper water level, ensure pump is

 

 

 

 

 

 

 

primed and/or check for clogged filter.

 

 

 

 

 

 

 

Pressure switch may need to be adjusted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure switch problem:

 

 

Call your dealer for service.

 

 

 

 

Pressure switch is closed, while pump is

 

 

 

 

 

 

 

deactivated. Pressure switch may need to

 

 

 

 

 

 

 

be adjusted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool condition:

 

 

 

 

 

 

 

If the water temperature drops 20°F

 

 

No corrective action is required.

 

 

 

 

(11°C) below the set temperature, the low

 

 

 

 

 

 

 

 

 

 

 

 

 

speed pump and the heater will activate to

 

 

 

 

 

 

 

bring the temperature within 15°F (8°C) of

 

 

 

 

 

 

 

the set temperature.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Freeze condition:

 

 

No action is required.

 

 

 

 

A potential freeze condition has been

 

 

The low speed pump will be activated along

 

 

 

 

detected (55°F / 12.8°C.)

 

 

with the heater. The spa will automatically

 

 

 

 

 

 

 

heat, until the spa is out of danger (65°F /

 

 

 

 

 

 

 

18.3°C.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

Image 40
Contents Page Aquatic Fitness System Table of Contents Draining Your Aquatic Fitness System Important Safety Instructions Read and Follow ALL Instructions CarefullyFollowing strenuous exercise Aquatic Fitness System Hyperthermia Do’s Don’tsDimension One Spas, Inc Aquatic Fitness System Features HydroTherapy JetsSwim Jets HydroSport Aquatic Fitness GearRowing Seat Swim Tether MountsBuilt-in OptiMounts Multiple Training StationsAquatic Fitness System Equipment Pack Using The Top Side Control Using Your Aquatic Fitness SystemBefore you Start Temperature Set Buttons Jets 1 ButtonLight Button Jets 2 and Jets 3 ButtonsLED Display Window Programming the Filtration Cycle FiltrationStandard Mode Filter CyclesEconomy Mode Lockout Mode Temperature display flashes in this functionAdditional Features Following features are included on your hot tubSpa Included Heater and Circulation Pump ControlOperation of the Spa Jets Button LED Digital Display WindowAquaFit Dual Temp Up and Down Buttons Program the Filter Cycle Start Time by pressing Program ButtonProgram the Filter Cycle Duration by pressing the Program Temperature Unit Heat Indicator LightHeat Indicator Light Dimension One Spas Icon Logo ButtonOH Overheat Protection Digital Display MessagesFlashing LED on the Control Panel Do not Enter the Water if you see a flashing Flashing Temperature onDisplay Routine Equipment Maintenance Filter CleaningDraining Your Aquatic Fitness System SPA AquaFit Dual Temp OnlyLight Bulb Replacement Surface Care Shell Dimension One EnviroTect Skirts and Vinyl CoversCare for the Wood Spa Cabinet Special Cold Weather Instructions Procedure for WinterizingItems Required for Winterizing Aquatic Fitness System Replace all equipment access panels onto the system Spring Time StartupWarranty Service Information Do not block the air intakesAquatic Fitness System is heating Glossary of TermsUsed to drain your Aquatic Fitness System Light Skimmer Door Aquatic Fitness System side control panelTroubleshooting Guide Heating SystemElectrical System Water SystemSelf-Diagnostic Control System AquaFit, AquaFitDual Temp Pool-Side, AquaProHigh temperature condition AquaFitDual Temp Spa-SideTemperature Probe Failure Call the dealer for service