Dimension One Spas 2003 Troubleshooting Guide, Heating System, Electrical System, Water System

Page 39

Aquatic Fitness System

2003 Owner’s Manual

Troubleshooting Guide

Heating System

 

 

 

 

 

 

 

 

Symptom

 

Problem

Corrective Action

 

Does not heat

 

1.

Temperature setting is too low

1.

Turn up the thermostat

 

 

 

2.

Dirty filter

2.

Clean filter

 

 

 

3.

Flow switch out of adjustment

3.

Call for service

 

 

 

 

 

 

 

 

Too hot

 

1.

Temperature setting is to high

1.

Turn down the thermostat

 

 

 

2.

High limit tripped

2.

Call for service

 

Flashing temperature of 34°F or 134°F

 

Possible temperature sensor failure

Call for service

 

appears on the display

 

 

 

 

 

Electrical System

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

Problem

 

Corrective Action

 

 

 

Will not turn on – in any mode

 

No power

 

Check circuit breaker and/or GFCI

 

 

 

Turns on by itself

 

Normal automatic daily power filtration, or

 

No action required

 

 

 

 

 

anti-freeze cycle

 

 

 

 

 

 

 

Light is out

 

Burned out bulb

 

Replace bulb

 

 

 

 

Pump shuts down unexpectedly while in

 

1. Automatic 30-minute timer has shut

 

1. Push JETS pad again to start another

 

 

 

use

 

pump off

 

 

30-minute cycle

 

 

 

 

 

2. Motor over-heated and automatic

 

2. If pump(s) will not restart when JETS

 

 

 

 

 

protective device has shut down

 

 

pad is pushed, call for service

 

 

 

 

 

pump(s)

 

 

Make sure that the equipment panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

vent area is not blocked. Vent

 

 

 

 

 

 

 

 

blockage can cause serious damage to

 

 

 

 

 

 

 

 

your equipment.

 

 

 

3 flashing LEDs appear on the Top Side

 

Possible sensor errors

 

1.

Check water level

 

 

 

Control

 

 

 

2.

Clean filter

 

 

 

 

 

 

 

 

If problem persists:

 

 

 

 

 

 

 

 

1.

Turn off power

 

 

 

 

 

 

 

 

2.

Restart the system

 

 

 

 

 

 

 

If problem persists:

 

 

 

 

 

 

 

 

Call for service

 

Water System

 

 

 

 

 

 

 

 

 

Symptom

 

Problem

 

Corrective Action

 

Pulsating jets

 

Water level too low

 

Fill with water to 1” to 2” (2 to 5

 

 

 

 

 

 

centimeters) above the bottom of the tile

 

 

 

 

 

 

line

 

 

No Jet Action, or action is poor

 

1.

HydroTherapy Jets closed

 

1.

Open Jets

 

 

 

2.

Diverter Valve turned

 

2.

Turn the Diverter Valve clockwise or

 

 

 

 

 

 

 

counter clockwise

 

 

 

3.

Dirty Filter

 

3.

Clean Filter

 

 

 

4.

Air lock

 

4.

Loosen pump union to allow air to

 

 

 

 

 

 

 

escape

 

 

 

5.

Gate valve closed

 

5.

Open gate valve

 

The water is cloudy or has a smell

 

The water has a chemical imbalance.

 

1.

Check TA/pH

 

 

 

 

 

 

2.

Test and adjust

 

 

 

 

 

 

3.

Change Water if necessary

 

 

 

 

 

 

 

 

35

Image 39
Contents Page Aquatic Fitness System Table of Contents Draining Your Aquatic Fitness System Read and Follow ALL Instructions Carefully Important Safety InstructionsFollowing strenuous exercise Aquatic Fitness System Hyperthermia Don’ts Do’sDimension One Spas, Inc HydroSport Aquatic Fitness Gear Aquatic Fitness System FeaturesHydroTherapy Jets Swim JetsMultiple Training Stations Rowing SeatSwim Tether Mounts Built-in OptiMountsAquatic Fitness System Equipment Pack Using Your Aquatic Fitness System Using The Top Side ControlBefore you Start Jets 1 Button Temperature Set ButtonsJets 2 and Jets 3 Buttons Light ButtonLED Display Window Filtration Programming the Filtration CycleFilter Cycles Standard ModeEconomy Mode Temperature display flashes in this function Lockout ModeHeater and Circulation Pump Control Additional FeaturesFollowing features are included on your hot tub Spa IncludedOperation of the Spa LED Digital Display Window Jets ButtonAquaFit Dual Temp Up and Down Buttons Program Button Program the Filter Cycle Start Time by pressingProgram the Filter Cycle Duration by pressing the Program Dimension One Spas Icon Logo Button Temperature UnitHeat Indicator Light Heat Indicator LightDigital Display Messages OH Overheat ProtectionFlashing LED on the Control Panel Flashing Temperature on Do not Enter the Water if you see a flashingDisplay SPA AquaFit Dual Temp Only Routine Equipment MaintenanceFilter Cleaning Draining Your Aquatic Fitness SystemLight Bulb Replacement Dimension One EnviroTect Skirts and Vinyl Covers Surface Care ShellCare for the Wood Spa Cabinet Procedure for Winterizing Special Cold Weather InstructionsItems Required for Winterizing Aquatic Fitness System Spring Time Startup Replace all equipment access panels onto the systemDo not block the air intakes Warranty Service InformationGlossary of Terms Aquatic Fitness System is heatingUsed to drain your Aquatic Fitness System Light Aquatic Fitness System side control panel Skimmer DoorWater System Troubleshooting GuideHeating System Electrical SystemAquaFit, AquaFitDual Temp Pool-Side, AquaPro Self-Diagnostic Control SystemAquaFitDual Temp Spa-Side High temperature conditionTemperature Probe Failure Call the dealer for service