Trouble-shooting and Maintenance

Inspect and tighten all parts each time you use the weight system. Replace any worn parts immediately. The weight system can be cleaned using a damp cloth and mild non-abrasive detergent. Do not use sol- vents.

Note: If any of the following adjustments are made to the weight system, the weight mechanism must also be adjusted. Please refer to steps 38a to 38g on pages 16 and 17 to perform these adjustments.

TIGHTENING THE CABLES

Woven cable, the type of cable used on the weight sys- tem, can stretch slightly when it is first used. If there is slack in the Cables before resistance is felt, the Cables should be tightened. Slack can be removed from the cables in several different ways:

Slack can be removed by moving the ÒVÓ-Pulley (6) to one of the other holes in the welded tube on the Seat Frame (36). To do this, remove the 3/8Ó x 3 1/4Ó Bolt (69), Cable Trap (66), 3/8Ó Flat Washer (55) and 3/8Ó Nylon Locknut (63). Move the ÒVÓ-Pulley and re-attach it with the Bolt, Washer, Cable Trap and Locknut.

Note: If a Cable tends to slip off the Pulleys often, the Cable may have become twisted. Remove the Cable and re-install it.

If the Cables need to be replaced, see ORDERING REPLACEMENT PARTS on the back cover of this manual.

1

36

Welded

Tube

63

55

6

66

69

Additional slack can be removed by using the Pulley Plates (31). The Pulley Plates have several sets of adjust- ment holes. By moving one or both pulleys to a different set of holes, the cables will be tightened.

To move a Pulley, remove the 3/8Ó Nylon Jamnut (63) and the 3/8Ó x 1 1/2Ó Bolt (60). Remove the Cable Trap (66) and the Pulley (35) from the Pulley Plates (31). Re-attach the Pulley and the Cable Trap to the appropriate hole in the Pulley Plates. Note: Begin by moving one Pulley to the second adjustment hole. If the Cables are still too loose, move the same Pulley to the third hole. If addi- tional adjustment is needed, move the second Pulley until the Cables are tight.

 

Adjustment

31

Holes

 

66

60

 

 

63

 

35

22

Image 22
Contents QUESTIONS? Model No. WESY92190 Serial NoTable of Contents Important Precautions Before You Begin DecalAssembly Frame Assembly Do not tighten the Nylon Locknuts yetTighten all of the Nylon Locknuts used in steps 3 to Support Plate 27 is oriented as shown Open the parts bag labeled Òarm ASSEMBLY.ÓCap is angled as shown in the inset drawing Left Nylon Jamnut. The Leg Lever should pivot freelyRight Cable Assembly Page Page Tube Seat Assembly Open the parts bag labeled Òseat ASSEMBLY.ÓPage Page Screw must pivot freely Power Cable ID Chart Low Cable Cable Diagram High Cable How to Use the Weight System Plugging in the Power CordUsing the Curl Post Trouble-shooting and Maintenance Tightening the CablesPage Part Identification ChartÑWESY92190 Page Part ListÑModel No. WESY92190 Qty DescriptionExploded Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT