TROUBLESHOOTING

Inspect and tighten all parts each time the weight system is used. Replace any worn parts immediately. The weight system can be cleaned using a damp cloth and mild non-abrasive detergent. Do not use solvents.

TIGHTENING THE CABLES

Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is slack in the cables before resistance is felt, the cables should be tightened.

To tighten the cables, first insert the weight pin into the middle of the weight stack. Slack can be removed from these cables several ways:

See drawing 1. Loosen the 1/2” Plain Nut (45) on the Weight

1

 

Cable (72) bolt, away from the 1/2” Flat Washer (11). Screw

 

 

72

the bolt a few turns into the Weight Tube (17). Retighten the

 

1/2” Plain Nut down onto the 1/2” Flat Washer.

 

45

 

 

 

 

11

 

 

17

See drawing 2. Remove either the upper or lower 3/8” Nylon

2

 

Locknut (50) and 3/8” x 2” Bolt (54) from the Adjustable

 

 

 

Pulley Plates (23). Remove the 3 1/2” Pulley (24) and the

 

23

Cable Trap (25). Reattach the 3 1/2” Pulley and the Cable

 

Trap to a hole closer to the center of the Adjustable Pulley

 

54

 

 

Plates with the 3/8” x 2” Bolt and 3/8” Nylon Locknut.

25

 

 

50

Either set of Adjustable Pulley Plates (23) can be adjust-

 

 

 

ed in this manner.

 

24

Do not overtighten the cables. If the cables are over tightened, the top weight will be lifted off the weight stack. If a cable tends to slip off the pulleys often, it may have become twisted. Remove the cable and re-install it.

If the cables need to be replaced, see ORDERING REPLACEMENT PARTS on the back cover of this manual.

24

Image 24
Contents QUESTIONS? Model No. WESY37531 Serial NoTable of Contents Important Precautions Using the weight system. If you have additional Before YOU BeginFor your benefit, read this manual carefully before Assembly Make Assembly EasierFrame Assembly Nylon Locknuts yetDo not tighten the Nylon Locknuts 50 yet Do not tighten the Nylon Locknuts yet Locate and open the parts bag labeled ARM Assembly Tighten the Nylon Locknuts 50 used in stepsPage Cable Assembly Nylon Jamnut the Leg Lever must pivot easilyTrap is turned to hold the Cable in place Page Weight Cable is in the groove of the 3 1/2 Pulley Cable Trap is turned to hold the Cable in place Cable Trap is turned to hold the Cable in place Locknut yet Page Seat Assembly Locate and open the parts bag labeled Seat AssemblyPage Adjustments Changing the Weight SettingAttaching the AB Strap to the AB Pulley Station Weight Resistance Chart PlatesTroubleshooting Tightening the CablesCable Diagrams Weight Cable Cable ID Stack Low Pulley Page 2 Square Inner Cap 3 Inner Cap 2 x 2 1/2 Inner Cap Part Identification CHART-Model No. WESY37531 R1003AX 4 Bolt X 4 3/4 Bolt X 5 1/2 Bolt Part LIST-Model No. WESY37531 Qty DescriptionModel No. WESY37531 Ordering Replacement Parts Limited WarrantyIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT