Whirlpool W10120482A installation instructions Check Operation, Technical Specification

Page 11

Check Operation

1.Check that you:

did not skip any steps.

installed all parts.

properly installed dryer legs.

leveled dryer.

have secured all exhaust vent joints with 100 mm (4") clamps.

have all the tools you started with.

2.Plug power supply cord into earthed outlet or connect direct wire to power supply. Turn power supply on.

3.Read the Use and Care Guide to fully understand your new dryer. Select a full heat cycle (not the air cycle) and start dryer. After five minutes, open dryer door. You should feel heat inside dryer.

If the burner did not ignite and you do not feel heat inside the dryer, shut the dryer off for 5 minutes, then check the following:

electrical supply is connected.

house fuse is intact and tight; or circuit breaker has not tripped.

dryer door is closed.

controls are set in a running or “On” position.

start button has been pushed firmly.

If dryer makes an unusual noise, check that the dryer is level.

Technical Specification

Moving dryer to a new location?

Check with a qualified electrician to confirm that supply voltage at new home matches voltage specified on the model/serial rating plate.

Remove power cord plug from power supply.

 

Tape top

 

to cabinet.

 

Tape

Have a qualified

door to

gas technician

front

shut off and

panel.

disconnect the

 

gas supply to

 

the dryer.

 

 

Turn

 

leveling

 

legs all the

 

way in.

Slide dryer onto cardboard or hardboard before moving it across the floor to prevent damaging floor covering.

220-240V~50Hz 1ph 3A max. IPX4 Clothes capacity: 9.1 kg max.

Factory set for NATURAL GAS:

Injector size: 2.2 mm Heat input gross: 5.9 kW

 

 

 

 

European Country:

 

GB, ES, PT

GR, IT

 

 

 

 

European Gas Category:

 

II2H3+

II2H3B/P

Gas Flow Rate:

 

0.562703 m3/hr

0.562703 m3/hr

Supply pressure (G20):

 

20 mbar

20 mbar

 

 

 

 

Factory adjusted pressure:

 

7.4 mbar

7.4 mbar

 

 

 

With LPG conversion kit: Injector size: 1.25 mm Heat input

gross: 5.7 kW

 

 

 

 

European Country:

 

GB, ES, PT

GR, IT

 

 

 

 

European Gas Category:

 

II2H3+

II2H3B/P

Butane supply pressure (G30):

 

28-30 mbar

30 mbar

 

 

 

 

Adjusted pressure:

 

N/A

N/A

 

 

 

 

Propane supply pressure (G31):

 

37 mbar

30 mbar

 

 

 

 

Adjusted pressure:

 

N/A

N/A

NOTE: Conversion kit : From Natural Gas to LP Gas : Whirlpool Part No. 279918.

Manufacturer : Whirlpool Corporation, Benton Harbor, Michigan 49022, USA.

11

Image 11
Contents W10120482A Dryer Safety Table of ContentsWhat to do if YOU Smell GAS Location Requirements Installation RequirementsTools and Parts Minimum Installation Clearances Recessed Area and Closet Installation InstructionsProduct Dimensions Gas Requirements Electrical RequirementsVenting Requirements Flexible Metal Vent Vent System LengthMaximum Vent Length Rigid Metal VentPrepare Dryer Installation Instructions GAS DryerInstall Ventwork Level and Exhaust the Dryer Check Operation Technical SpecificationSeguridad DE LA Secadora ÍndicePasos QUE Usted Debe Seguir SI Huele a GAS Requisitos de ubicación Requisitos DE InstalaciónPiezas y herramientas Espacios mínimos para la instalación Instrucciones para la instalación empotrada o en clósetMedidas del producto Requisitos del suministro de gas Requisitos eléctricosRequisitos de ventilación Ducto de escape de metal flexible Largo del sistema de ventilaciónLongitud máxima del ducto de escape Ducto de escape de metal rígidoPreparación de la secadora Instalación de la ventilaciónNivelación y ventilación de la secadora Especificaciones técnicas Verifique el funcionamientoSecurite DU SECHE-LINGE Table DES MatieresQUE Faire Dans LE CAS D’UNE Odeur DE GAZ Outillage et pièces Exigences DinstallationExigences demplacement Dégagements de séparation minimums Dimensions de lappareilExigences concernant lalimentation en gaz Spécifications électriquesExigences concernant l’évacuation Conduit métallique flexible Longueur du système d’évacuationLongueur maximale du conduit Conduit métallique rigidePréparation du sèche-linge Installation du dispositif d’évacuationMise à niveau et évacuation du sèche-linge Caractéristiques techniques Contrôle du fonctionnementW10120482 AImpreso en EE.UU. Imprimé aux E.-U 2007 01/2007