Door clearance | Dryer dimensions |
dimensions |
|
|
Location must be large enough to fully open dryer door.
dryer
6"*exhaust
*Dimensions shown with feet extended 1"
vent
from bottom of dryer.
Large side swing door (reversible)
gas burner inlet pipe connection at rear of dryer
29"
28" max.
7"
Closet/confined area installation
Front view | Side view |
Recessed area installation
WARNING — To reduce the risk of fire
Small side swing door
48 sq.in.** | closet door | |
|
| |
|
| 3" |
|
| 14" |
| max. | |
|
| |
|
| 3" |
| 24 sq.in.** | 1" |
|
| spacing |
| 5" is recommended *** | |
|
| 4" is minimum |
| ** Minimum top and bottom air openings for | |
closet door. |
***External exhaust elbow requires recommended spacing.
If a closet door is installed: The minimum unobstructed air openings
are required. Louvered doors with | ||||
| ||||
| equivalent air openings are |
| ||
| acceptable. |
|
| |
| Installation clearances. |
| ||
Use recommended clearance for | ||||
| easier installation. |
|
| |
|
|
| ||
|
| Recommended/minimum | ||
| Back | Sides | Top | Front |
|
|
|
|
|
| 5"/4" | 1"/0" | 18"/18" | 1"/1" |
this appliance MUST BE EXHAUSTED OUTDOORS
Front view
18"
0"* | 0"* |
*Wall, door and floor molding may require additional spacing.
•A clothes dryer produces combustible lint and must be exhausted outdoors.
•If codes permit, dryer may be installed in a recessed area or closet using dimensions shown.
•Dimensions are in inches and are the minimum allowable.
•Additional spacing should be considered for ease of installation and servicing. Companion appliance spacing should also be considered.
Installation clearances.
Use recommended clearance for easier installation.
Recommended/minimum
Back Sides Top Front
5"/0" 1"/0" 18"/18" —
4