Whirlpool 8535845 Natural Gas, Burner input requirements, Supply line requirements

Page 6

Natural Gas:

This dryer is equipped for use with NATURAL GAS. It is design-certified by CSA International for L.P. (propane or butane) gases with appropriate conversion.

L.P. Gas:

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier.

Conversion must be done by a qualified service technician. Gas conversion kit part numbers are listed on the gas valve burner base.

Burner input requirements:

Elevations up to 10,000 feet:

The design of this dryer has been certified by CSA International for use at altitudes up to 10,000 feet above sea level at the B.T.U. rating indicated on the model/serial rating plate. Burner input adjustments are not required when the dryer is operated up to this elevation.

Elevations above 10,000 feet:

When installed above 10,000 feet, a four percent (4%) reduction of the burner B.T.U. rating shown on the model/serial rating plate is required for each 1,000 foot increase in elevation. For assistance installing dryer above 10,000 feet elevation, contact your serving gas supplier.

Supply line requirements:

Provide a 1/2-inch IPS rigid gas supply line to the dryer location.

An individual manual shutoff valve must be installed within 6 feet of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1 latest edition*.

shutoff valve “open” position

to dryer

rigid gas supply line

Recommended gas line connection method.

If local codes permit, it is recommended that new flexible metal tubing, design-certified by AGA or CSA, be used for connecting the appliance to the rigid gas supply line.

(The gas pipe which extends through the lower rear of the appliance has 3/8-inch male pipe thread.)

Optional gas line connection method.

When acceptable to the gas supplier and local codes, 3/8-inch approved tubing may be used for lengths under 20 feet. For lengths over 20 feet, larger tubing should be used.

A combination of pipe fittings must be used to connect the dryer to the gas line.

Pipe-joint compounds resistant to the action of L.P. gas must be used.

An elbow and connector between tubing and dryer pipe may be needed to prevent kinking.

A 1/8-inch NPT plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer.

The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi.

The dryer must be isolated from the gas supply piping system by closing the equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi.

Copies of the standards listed may be obtained from:

*CSA International

8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575

6

Image 6
Contents Have questions about your dryer? Set to operate on Natural GASIt is your responsibility to Your safety and the safety of others are very importantFor proper drying performance What to do if YOU Smell GASParts needed for installation Venting systemDimensions Closet/confined area installationDoor clearance Recommended ground method Electrical RequirementsGas supply Observe ALL Governing Codes and OrdinancesNatural Gas Burner input requirementsSupply line requirements Mobile home installation requirements Dryer must be fastened to the floorDryer must be exhausted outside Preferred Plan the exhaust vent installationDetermine vent length AcceptablePrepare the dryer Installation stepsInstall vent system Changing door swingLevel dryer Make gas connectionExhaust dryer Dura Safe Check operationMoving dryer to a new location? Whirlpool CorporationInstrucciones de instalación Para funcionar con GAS NaturalPara el debido funcionamiento de la secadora Es su responsabilidadQUÉ Hacer SI HAY Olor a GAS Sistema de salida de aire Campana exterior de salida de aireLas instalaciones en casas móviles o rodantes requieren Dimensiones de los espacios para la puerta Si se instala una puerta para el closetSuministro de gas Método recomendado de puesta a tierraObserve Todos LOS Códigos Y Reglamentos Aplicables Requisitos de entrada del quemador Gas naturalGas licuado Propano líquido/L.P Requisitos de la línea de suministroExterior de salida de Requisitos del Sistema de salida De aireRequisitos de instalación en una casa móvil o rodante La secadora debe fijarse al pisoDetermine la longitud del conducto PreferidoAceptable Prepare la secadora Etapas de la InstalaciónInstale el sistema de salida de aire Para invertir el sentido de la apertura de la puertaNivelación de la secadora Puerta lateral superanchaConexión del gas Salida de aire de la secadoraVerifique el funcionamiento ¿Va a trasladar de lugar la secadora? Los conjuntos facilitan la instalación