Exhaust requirements

WARNING

Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

Do Not use non-metal flexible vent, or exhaust hoods with magnetic latches.

Do Not exhaust dryer into any gas vent, chimney, furnace, cold air vent, wall, ceiling, concealed space of a building, attic or crawl space, or any other vent used for venting.

Do Not install flexible vent in enclosed walls, ceilings or floors.

Important: Observe all governing codes and ordinances.

Exhaust your dryer to the outside. Moisture and lint indoors may cause:

Lint to gather around the dryer where it can be fuel for a fire.

Moisture damage to woodwork, furniture, paint, wallpaper, carpet, etc.

Housecleaning problems and health problems.

Dura Safe™ venting products are recommended and are available from your dealer.

Four-inch diameter vent must be used.

Use a heavy metal vent. Do Not use plastic or metal foil vent.

Rigid metal vent is recommended to prevent crushing and kinking.

Flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible vent to avoid sagging and kinking that may result in reduced air flow.

An exhaust hood should cap the exhaust vent to prevent rodents and insects from entering the home.

Exhaust outlet hood

 

 

 

 

 

must be at least 12

 

 

12"

 

 

inches from the ground

 

 

minimum

or any object that may

 

 

 

 

 

be in the path of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exhaust (such as

 

 

 

 

 

flowers, rocks or

 

 

 

 

 

bushes, etc.).

 

 

 

 

 

If using an existing exhaust system, clean lint from entire length of system and make sure exhaust hood is not plugged with lint.

Replace any vinyl or metallized plastic foil vent with rigid metal or flexible metal vent.

Use clamps to seal all joints. Do Not use duct tape, screws or other fastening devices that extend into the interior of the vent to

secure vent.

Service check: Back pressure in any exhaust system used must not exceed

0.6inches in water column measured with an incline manometer at the point that exhaust vent connects to dryer.

Mobile home installation requirements

If codes permit, this dryer is suitable for mobile home installations. The installation of the dryer must conform to the U.S. Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Homes Construction and Safety, Title 24, HUD Part 280) latest edition.

The dryer must be fastened to the floor.

Order Mobile Home Installation Kit, Part No. 346764, from your dealer. Kit includes the necessary fastening hardware and detailed installation instructions. Metal exhaust system is also available through your dealer.

Special provisions must be made for the introduction of outside air into the dryer when installed in a mobile home. The area of any opening for the introduction of outside air (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

 

outside

 

wall

floor

 

enclosed

skirting

area

 

The dryer must be exhausted outside.

The exhaust vent must be securely fastened to a non-combustible portion of the mobile home structure and must not terminate beneath the mobile home.

7

Image 7
Contents Set to operate on Natural GAS Have questions about your dryer?What to do if YOU Smell GAS Your safety and the safety of others are very importantFor proper drying performance It is your responsibility toVenting system Parts needed for installationCloset/confined area installation DimensionsDoor clearance Observe ALL Governing Codes and Ordinances Electrical RequirementsGas supply Recommended ground methodBurner input requirements Natural GasSupply line requirements Dryer must be fastened to the floor Mobile home installation requirementsDryer must be exhausted outside Acceptable Plan the exhaust vent installationDetermine vent length PreferredChanging door swing Installation stepsInstall vent system Prepare the dryerMake gas connection Level dryerExhaust dryer Check operation Dura SafeWhirlpool Corporation Moving dryer to a new location?Para funcionar con GAS Natural Instrucciones de instalaciónEs su responsabilidad Para el debido funcionamiento de la secadoraQUÉ Hacer SI HAY Olor a GAS Campana exterior de salida de aire Sistema de salida de aireLas instalaciones en casas móviles o rodantes requieren Si se instala una puerta para el closet Dimensiones de los espacios para la puertaMétodo recomendado de puesta a tierra Suministro de gasObserve Todos LOS Códigos Y Reglamentos Aplicables Requisitos de la línea de suministro Gas naturalGas licuado Propano líquido/L.P Requisitos de entrada del quemadorLa secadora debe fijarse al piso Requisitos del Sistema de salida De aireRequisitos de instalación en una casa móvil o rodante Exterior de salida dePreferido Determine la longitud del conductoAceptable Para invertir el sentido de la apertura de la puerta Etapas de la InstalaciónInstale el sistema de salida de aire Prepare la secadoraPuerta lateral superancha Nivelación de la secadoraSalida de aire de la secadora Conexión del gasVerifique el funcionamiento Los conjuntos facilitan la instalación ¿Va a trasladar de lugar la secadora?