Whirlpool 240-volt installation instructions Alternate Connection

Page 13

5.Connect the other two wires to outer terminal block screws using the same method(s) described in step 4. Tighten all terminal block screws firmly.

6.Tighten the strain relief screws.

7.Insert tab of terminal block cover into slot of the dryer rear panel. Secure cover with hold-down screw.

NOTE: If local codes do not permit the connection of a frame-grounding conductor to the neutral wire, see the instructions for “Alternate Connection.”

Alternate Connection:

If local codes do not permit the connection of a frame-grounding conductor to the neutral wire:

1.Disconnect power.

2.Make sure the power supply cord or direct wire cable is in place (see steps 1-3 on page 10 for power cord connections or steps 1-3 on pages 11 and 12 for direct wire connection).

3.Remove the neutral grounding wire (green/yellow wire) from external ground- ing connector screw. Loosen or remove terminal block screws. Connect neutral grounding wire and the neutral wire (white or center) of power supply cord or direct wire cable under the center screw of the terminal block.

4.Connect the other two wires to outer termi- nal block screws. Tighten all terminal block screws firmly.

5.Tighten the strain relief screws.

6.Insert tab of terminal block cover into slot of the dryer rear panel. Secure cover with hold-down screw.

7.Connect separate copper grounding wire from external ground connector to an adequate ground. If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate.

INSTALLATION INSTRUCTIONS

External

Neutral

ground

grounding wire

connector

(green/yellow)

Grounding path determined by a qualified electrician

Alternate 3-Wire Connection with External-Grounding Conductor

13

Image 13
Contents 3977625 Volt Compact Electric DryerPlease record your model’s information Thank you for buying a Whirlpool applianceYour safety and the safety of others is very important Dryer SafetyImportant Safety Instructions Before starting installation Installation InstructionsInstallation How to install your dryerParts supplied with the dryer Installing the leveling legs Electrical Requirements Connecting ToElectrical Connection Options If Your Home Has You Will BeGrounding Instructions Three-Wire Electrical Connection to ReceptacleHold-down screw Wire Connection with Frame-Grounding ConductorOn next Three-Wire Electrical Connection Direct WireWhite Alternate Connection Grounding Instructions Make Four-Wire Electrical Connection to ReceptacleWire Connection with Frame-Grounding Conductor Fire Hazard Four-Wire Electrical Connection Direct WireBare copper wire Neutral Exhaust requirements Exhaust airflow To determine maximum vent length Determining vent lengthExhaust Hood Type Minimum installation spacing Recessed area and closet installationMobile home installation Parts and Features Starting your dryer Using Your DryerStopping and restarting your dryer Selecting the right cycle and setting End of cycle signalLoading Automatic Permanent Press/ Regular Cycle Type of Load Cycle Selecting the right cycle and settingEvery load cleaning Cleaning the lint screenAs needed cleaning Caring for Your DryerRemoving accumulated lint from inside the dryer cabinet Cleaning the dryer interiorCommon drying problems TroubleshootingProblem Cause Solution Stains on Lint in loadLoad ItemsIf you need assistance or service Assistance or ServiceIf you need replacement parts Assist you. When callingWhirlpool Dryer Warranty