Whirlpool 240-volt Troubleshooting, Common drying problems, Problem Cause Solution

Page 30

Troubleshooting

Common drying problems

PROBLEM

CAUSE

SOLUTION

Not drying

• Lint screen is clogged with lint. • Clean lint screen.

satisfactorily

• Restricted air movement.

• Run dryer for 5-10 minutes. Hold

 

 

Exhaust vent or outside exhaust

hand under outside exhaust hood to

 

hood is clogged with lint.

check air movement. If you do not

 

 

feel air moving, clean exhaust system

 

 

of lint or replace exhaust vent with

 

 

heavy metal or flexible metal vent

 

 

(see “Installation Instructions”).

Exhaust vent is crushed or kinked.

Replace with heavy metal or flexible metal vent (see your “Installation Instructions”).

Cycle and Temperature Control knob is set on Air cycle.

Select the right cycle and for the types of garments being dried (see “Using Your Dryer”).

Fabric softener sheets blocking exhaust grill.

Dryer located in room with temperature below 45ºF.

Large amount of moisture in the load.

Cold rinse water used.

Load too large and bulky to dry quickly.

Use only one softener sheet per load and only use it once.

Move dryer to a location with temperatures above 45ºF.

Expect longer dry times with items that hold more moisture (cottons).

Expect longer dry times.

Separate load to tumble freely.

Dryer will

• Power cord not firmly plugged • Plug power cord into a live circuit.

not run

into a live circuit with proper

 

voltage.

Fuse blown or circuit breaker tripped.

Using a regular fuse.

Dryer door not firmly closed.

Start button not firmly pressed.

Cycle and Temperature Control knob set to Off.

Replace fuse or reset breaker.

Replace with a time-delay fuse.

Close dryer door tightly.

Press Start button again.

Set knob to a cycle or time.

30

Image 30
Contents Volt Compact Electric Dryer 3977625Thank you for buying a Whirlpool appliance Please record your model’s informationDryer Safety Your safety and the safety of others is very importantImportant Safety Instructions Installation Instructions Before starting installationHow to install your dryer InstallationParts supplied with the dryer Installing the leveling legs Electrical Connection Options Connecting ToElectrical Requirements If Your Home Has You Will BeThree-Wire Electrical Connection to Receptacle Grounding InstructionsWire Connection with Frame-Grounding Conductor Hold-down screwThree-Wire Electrical Connection Direct Wire On nextWhite Alternate Connection Make Four-Wire Electrical Connection to Receptacle Grounding InstructionsWire Connection with Frame-Grounding Conductor Four-Wire Electrical Connection Direct Wire Fire HazardBare copper wire Neutral Exhaust requirements Exhaust airflow Determining vent length To determine maximum vent lengthExhaust Hood Type Recessed area and closet installation Minimum installation spacingMobile home installation Parts and Features Using Your Dryer Starting your dryerStopping and restarting your dryer End of cycle signal Selecting the right cycle and settingLoading Automatic Permanent Press/ Regular Cycle Selecting the right cycle and setting Type of Load CycleAs needed cleaning Cleaning the lint screenEvery load cleaning Caring for Your DryerCleaning the dryer interior Removing accumulated lint from inside the dryer cabinetTroubleshooting Common drying problemsProblem Cause Solution Load Lint in loadStains on ItemsIf you need replacement parts Assistance or ServiceIf you need assistance or service Assist you. When callingDryer Warranty Whirlpool