1.Disconnect power.
2.Remove
3.Attach a
4.Remove the center terminal block screw. Remove the neutral grounding wire (green/yellow wire) from external grounding screw.
INSTALLATION INSTRUCTIONS
Terminal block cover |
External ground | Center |
connector | terminal block screw |
5.Connect neutral grounding wire and the neutral wire (white) of power supply cord under the center screw of terminal block.
6.Connect the other two insulated wires to outer terminal block screws.
7.Connect the green, grounding wire from the power supply cord to the external grounding conductor screw. Tighten all terminal block screws firmly.
8.Tighten the strain relief screws.
9.Insert tab of terminal block cover into slot of the dryer rear panel. Secure cover with
Green/yellow wire of harness
External | Center | Neutral wire | |
terminal block screw | |||
ground | (white) | ||
| |||
connector |
|
|
Green wire |
|
| Neutral ground- |
of power supply |
|
| |
|
| ing wire | |
cord or bare |
|
| |
|
| (green/yellow) | |
copper wire |
| 3⁄4”, | |
|
|
| |
|
|
| strain relief |
4-Wire Connection with
Frame-Grounding Conductor
15