INSTALLATION INSTRUCTIONS
Four-Wire Electrical Connection (Direct Wire)
wWARNING
Fire Hazard
Use 10 gauge solid copper wire. Use a UL approved strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to follow these instructions can result in death, fire, or electrical shock.
GROUNDING INSTRUCTIONS
This appliance must be connected to a grounded metal, permanent wiring system; or an
SAVE THESE INSTRUCTIONS
The dryer can be connected directly to fused disconnect or circuit breaker box with
A conduit connector must be installed at junction box. Allow four feet of slack in the line so dryer can be moved if servicing is ever necessary.
1.Disconnect power.
•Strip 5 inches of outer covering from end of cable. Leave bare grounding wire at 5 inches.
•Cut 1 inch from 3 remaining
insulated wires. Strip insulation back 1 inch. Shape the end of each wire into a “U” shaped hook.
2.Remove
5"
1"
| 5" |
Terminal block cover |
|