Installation 39
i.e. the inside diameter of the drain pipe must be larger than the outside diameter of the drain hose.
The drain hose must not be kinked.
P1118
Important!
The drain hose may be extended to a maximum of 4 metres. An additional drain hose and joining piece is available from your local Service Centre.
Electrical connection
This machine is designed to operate on a
Check that your domestic electrical installation can take the maximum load required (2.2 kW), also taking into account any other appliances in use.
Connect the machine to an earthed socket.
The manufacturer does not accept any responsibility for damage or injury through failure to comply with the above safety precaution.
Should the power supply cable need to be replaced, this MUST be carried out by a Service Centre.
Permanent connection
In the case of a permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.
The switch must not break the yellow and green earth cable at any point. This operation must be performed by a qualified electrician.
The power supply cable must be easily accessible after installing the machine.