Alliance Laundry Systems WF235, WF305, WF185, WF150 Technical data WF400, IWF400, IWF090

Page 22

 

 

3

 

 

 

 

 

 

Technical data WF400, IWF400, IWF090

 

 

 

METRIC

US

Capacity (dry weight) Ratio [kg/Lit]

 

 

1:11

36,9 kg

81.35 lb.

1:10

40,1 kg

88.41 lb.

1:9

43,9 kg

96.78 lb.

Cylinder

 

 

Diameter

850 mm

33.46 inch

Depth

707 mm

27.83 inch

Volume

400 Lit

14.13 ft³.

Cabinet

 

 

Height

1412 mm

55.57 inch

Width

990 mm

38.98 inch

Depth

1360 mm

53.54 inch

Front loading

 

 

Diameter door opening

400 mm

15.74 inch

Door height

500 mm

19.68 inch

To center

700 mm

27.55 inch

Speed

 

 

Wash

 

10 - 50 tr/min - RPM

Distribution

 

85 tr/min - RPM

Spin

 

100 - 415 tr/min - RPM

G-factor

 

 

Spin

 

82

Motor (3-phase)

 

 

4p. 1470 tr./min

 

3 kW / 4,02 HP

Drain valve

 

 

 

 

3"

Water supply

 

 

Hard, soft, warm water

 

3/4"

Steam connection

 

 

Steam connection

 

1/2"

Heating

 

 

Electrical 230/400 V

 

18 kW

Electrical 400V

 

18 kW - 21 kW - 24 kW

Steam

 

X

Warm water (without additional heating)

X

Warm water (with additional heating)

X

Packing dimensions

 

 

(H x W x D) mm - inch

1560x1120x1470 mm - 61.41x 44.09x 57.87 inch

Weight

 

 

Net

560 kg

1234.59 lb.

Gross

605 kg

1333.80 lb.

22

Image 22
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Page Model Numbers Build-upPage Safety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data WF150, IWF150, IWF033, CWF033Dimensions WF150, IWF150, IWF033, CWF033 Technical data WF185, IWF185, IWF040, CWF185, CWF040 Dimensions WF185, IWF185, IWF040, CWF185, CWF040 Technical data WF235, IWF235, IWF055, CWF235, CWF055 Dimensions WF235, IWF235, IWF055, CWF235, CWF055 Technical data WF305, IWF305, IWF075, CWF305, CWF075 Dimensions WF305, IWF305, IWF075, CWF305, CWF075 Technical data WF400, IWF400, IWF090 Dimensions WF400, IWF400, IWF090 Anchoring on a metal base Installation and Connection InstructionsSurface Directly on the ground260 670 731 410 640 780 260 770 831 510 640 780 282 347 347 Water connection ModelWater drain Electrical Installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Machine Power Cable Connections Main power connectionConnection label Page Boiler Fed/Steam Heat Electric Heat Electrical Specifications WF150, IWF150, IWF033, CWF033Alternative Electric Heat Options Liters / 40 pounds Liters / 55 pounds Liters / 75 pounds Electrical Specifications WF400, IWF400, IWF090 Liters / 90 poundsLiquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingMaintenance instruction of the machine End of day General maintenance Periodical maintenanceAnnual maintenance Nameplate Contact InformationNameplate Location Replacement Parts Repair and after-sales service