Alliance Laundry Systems WF150, WF305, WF400, WF235, WF185 instruction manual Liters / 75 pounds

Page 39

4

WARNING

The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.

Electrical Specifications WF305, IWF305, IWF075, CWF305, CWF075

305 liters / 75 pounds

 

 

 

 

 

Boiler Fed/Steam Heat

 

Electric Heat

 

Code

Voltage

Cycle

Phase

Wire

Full Load Amps

 

Recommended Circuit Breaker (US-market)

AWG/mm2

kW Standard Heating Elements

Full Load Amps

 

Recommended Circuit Breaker (US- market)

AWG/mm2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US

NON-US

 

 

 

US

 

NON-US

 

N

440-480

50/60

3

3+PE

6

15

10

14/2.5

6x4 kW

32

50

 

50

8/10.0

P

380-415

50/60

3

3+N+PE

16

20

20

12/4.0

43

70

 

70

4/25.0

 

 

Q

200-240

50/60

3

3+PE

16

20

20

12/4.0

6x3 kW

60

70

 

70

4/25.0

X

200-240

50/60

1/3

2/3+PE

16

20

20

12/4.0

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

Alternative Electric Heat Options

N

440-480

50/60

3

3+PE

 

 

 

 

 

36

50

 

50

8/10.0

P

380-415

50/60

3

3+N+PE

 

 

 

 

3x3 kW +

48

70

 

70

4/25.0

Q

200-240

50/60

3

3+PE

 

 

 

 

3x4 kW

N/A

N/A

 

N/A

N/A

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

Table 6

 

 

 

 

 

 

 

39

Image 39
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Page Build-up Model NumbersPage Safety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data WF150, IWF150, IWF033, CWF033 Technical data and dimensionsDimensions WF150, IWF150, IWF033, CWF033 Technical data WF185, IWF185, IWF040, CWF185, CWF040 Dimensions WF185, IWF185, IWF040, CWF185, CWF040 Technical data WF235, IWF235, IWF055, CWF235, CWF055 Dimensions WF235, IWF235, IWF055, CWF235, CWF055 Technical data WF305, IWF305, IWF075, CWF305, CWF075 Dimensions WF305, IWF305, IWF075, CWF305, CWF075 Technical data WF400, IWF400, IWF090 Dimensions WF400, IWF400, IWF090 Directly on the ground Installation and Connection InstructionsSurface Anchoring on a metal base260 670 731 410 640 780 260 770 831 510 640 780 282 347 347 Model Water connectionWater drain Important Do not use fuses in place of a circuit breaker Electrical InstallationGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Electrical Specifications WF150, IWF150, IWF033, CWF033 Boiler Fed/Steam Heat Electric HeatAlternative Electric Heat Options Liters / 40 pounds Liters / 55 pounds Liters / 75 pounds Liters / 90 pounds Electrical Specifications WF400, IWF400, IWF090Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksEnd of day General maintenance Periodical maintenance Maintenance instruction of the machineAnnual maintenance Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service