Maintenance instruction of the machine
7
WARNING
To reduce the risk of electric shock, disconnect this appliance from the power supply before attempting any user maintenance. Turning the controls to the OFF position does not disconnect this appliance from the power supply.
Before starting wiring or inspection, power must be switched OFF, check to make sure that the operation panel indicator is off.
Any person who is involved in wiring or inspection shall wait for at least 10 minutes after the power supply has been switched OFF and check that there is no residual voltage using a tester or the like. The capacitor of the inverter or the EMC filter is charged with a high voltage for some time after power OFF, and it is dangerous.
End of day
General maintenance
Periodical maintenance
Clean AC drive filter:
a.Snap off external plastic cover which contains filter.
b.Remove foam filter from cover.
c.Wash filter with warm water and allow to air dry. Filter can be vacuumed clean.
Clean the entire cabinet of the machine regularly and remove all traces of soap, etc....
Remove all detergent residue in the soap dispenser with hot water.
Clean the door gasket and remove all detergents and other products.
Shut off the main water, steam, and power connections at the end of each day. Do not change the setting of the water inlet taps on boiler fed machines once these have been installed.
It is recommended to leave the door and soap dispenser open after use, to ventilate the machine.
Check for proper door lock operation on a daily basis.
The
Check the water inlet filters to make sure they are not blocked by calcification.
Check the drain valve for obstructions.
If a machine frequently skips the final spin, check whether the probe of the out of balance switch is still in the appropriate position, that is horizontally centered and vertically 1/3 from the bottom inside the window. (When the drum is empty).
Lubricate the bearings after every 200 hours of operation or replace the automatic lubricator annually.
46