Alliance Laundry Systems WF305, WF400, WF235, WF185, WF150 instruction manual Water connection, Model

Page 30

4

Water connection

The machine is delivered with hoses with 3/4" connections. These hoses fit the water inlet valves of the machine and the main water inlet taps. All the inlet valves have to be connected. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 3 and 5 bar (40 and 80 psi). If the pressure is too low, the cycle time will increase considerably.

In case of boiler fed machines, a minimum of hot water of 90°C - 194°F should be available per unit. (See Table 1)

MODEL

Min Contents Boiler

METRIC

US

 

For the WF150 = WF150, IWF150, IWF033, CWF033

116 l.

4.09 ft³

For the WF185 = WF185, IWF185, IWF040, CWF185, CWF040

145 l.

5.12 ft³

For the WF235 = WF235, IWF235, IWF055, CWF235, CWF055

150 l.

5.29 ft³

For the WF305 = WF305, IWF305, IWF075, CWF305, CWF075

180 l.

6.35 ft³

For the WF400 = WF400, IWF400, IWF090

240 l.

8.48 ft³

Table 1

MODEL

Inlet flow capacity per minute (Gallons / Liters)

INTERNATIONAL

US

 

 

For the WF150,

185

4.23 / 16

5.28 / 20

For the WF235,

305, 400

7.93 + 13.2 / 30 + 50

7.93 + 13.2 / 30 + 50

Table 2

To comply with the WRAS water regulations: an 'approved' single check valve or some other no less effective backflow prevention device shall be fitted at the point of connection(s) between the supply and the fitting (IRN R150).

30

Image 30
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Page Model Numbers Build-upPage Safety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data WF150, IWF150, IWF033, CWF033Dimensions WF150, IWF150, IWF033, CWF033 Technical data WF185, IWF185, IWF040, CWF185, CWF040 Dimensions WF185, IWF185, IWF040, CWF185, CWF040 Technical data WF235, IWF235, IWF055, CWF235, CWF055 Dimensions WF235, IWF235, IWF055, CWF235, CWF055 Technical data WF305, IWF305, IWF075, CWF305, CWF075 Dimensions WF305, IWF305, IWF075, CWF305, CWF075 Technical data WF400, IWF400, IWF090 Dimensions WF400, IWF400, IWF090 Anchoring on a metal base Installation and Connection InstructionsSurface Directly on the ground260 670 731 410 640 780 260 770 831 510 640 780 282 347 347 Water connection ModelWater drain Electrical Installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Electrical Specifications WF150, IWF150, IWF033, CWF033 Boiler Fed/Steam Heat Electric HeatAlternative Electric Heat Options Liters / 40 pounds Liters / 55 pounds Liters / 75 pounds Electrical Specifications WF400, IWF400, IWF090 Liters / 90 poundsLiquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingMaintenance instruction of the machine End of day General maintenance Periodical maintenanceAnnual maintenance Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service