Alliance Laundry Systems WF150, WF305, WF400, WF235, WF185 instruction manual Steam connection

Page 44

Steam connection

5

WARNING

Never touch internal or external steam pipes, connections, or components. These surfaces can be extremely hot and will cause severe burns. The steam must be turned off and the pipe, connections, and components allowed to cool before the pipe can be touched.

Machines with steam heating must have a steam valve between the steam installation and the machine.

5

3

4

3

2

1

6

 

 

 

 

 

 

 

 

7

With direct steam injection into the machine (See Table 8)

 

 

1.

Steam pipe

 

2.

Steam cut-off valve

 

3.

Pipe coupling

 

4.

Steam filter

 

5.

Magnetic steam valve

7

6.

Curve MF

7.

Steam hose with appropriate pipe coupling

 

7

 

 

 

 

Steam Supply Information

MODEL

inletSteam connection,inch

Numberof inletssteam

Recommended pressure,bar

Recommended pressure,psi

Maximum pressure,bar

Maximum pressure,psi

 

 

 

 

 

 

 

 

 

 

 

 

 

For the WF150 = WF150, IWF150, IWF033, CWF033

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the WF185 = WF185, IWF185, IWF040, CWF185, CWF040

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the WF235 = WF235, IWF235, IWF055, CWF235, CWF055

1/2

1

2.0 - 5.5

30 - 80

5.5

80

For the WF305 = WF305, IWF305, IWF075, CWF305, CWF075

1/2

1

2.0 - 5.5

30 - 80

5.5

80

For the WF400 = WF400, IWF400, IWF090

1/2

1

2.0 - 5.5

30 - 80

5.5

80

Table 8

44

Image 44
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Page Model Numbers Build-upPage Safety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data WF150, IWF150, IWF033, CWF033Dimensions WF150, IWF150, IWF033, CWF033 Technical data WF185, IWF185, IWF040, CWF185, CWF040 Dimensions WF185, IWF185, IWF040, CWF185, CWF040 Technical data WF235, IWF235, IWF055, CWF235, CWF055 Dimensions WF235, IWF235, IWF055, CWF235, CWF055 Technical data WF305, IWF305, IWF075, CWF305, CWF075 Dimensions WF305, IWF305, IWF075, CWF305, CWF075 Technical data WF400, IWF400, IWF090 Dimensions WF400, IWF400, IWF090 Installation and Connection Instructions SurfaceAnchoring on a metal base Directly on the ground260 670 731 410 640 780 260 770 831 510 640 780 282 347 347 Water connection ModelWater drain Electrical Installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Connection label Main power connectionMachine Power Cable Connections Page Alternative Electric Heat Options Electrical Specifications WF150, IWF150, IWF033, CWF033Boiler Fed/Steam Heat Electric Heat Liters / 40 pounds Liters / 55 pounds Liters / 75 pounds Electrical Specifications WF400, IWF400, IWF090 Liters / 90 poundsLiquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingMaintenance instruction of the machine End of day General maintenance Periodical maintenanceAnnual maintenance Nameplate Location Contact InformationNameplate Replacement Parts Repair and after-sales service