Grindmaster service manual American Metal Ware 87710E Coffee Urn

Page 14

American Metal Ware 87710E Coffee Urn

Page 15

Problem

 

Possible Cause

Service Check

Remedy

 

 

 

 

C) Auto refill fails to fill

3) Water strainer

Water pressure before

Remove and clean micromesh

water tank (continued).

clogged.

strainer and not after.

screen filter located in water strainer.

 

 

 

 

 

 

4)

No power on Dual

Check for 120V AC

If voltage missing or incorrect, check

 

Level Control.

across “H” and “N” ter-

wiring for looseness, breaks, and

 

 

 

minals.

proper connections.

 

 

 

 

 

 

5)

Fill solenoid valve

Disassemble.

Clean out and/or replace plunger

 

clogged with scale or

 

assembly or entire valve. May

 

frozen closed.

 

require new coil. Caution is advised

 

 

 

 

to avoid damage to valve. See valve

 

 

 

 

instruction sheet.

 

 

 

 

 

 

6)

Fill solenoid valve

Jumper from “FILL” ter-

Replace coil. Also check for frozen

 

coil inoperative.

minal to “H” terminal

plunger. See valve instruction sheet.

 

 

 

does not start fill.

 

 

 

 

 

 

 

7)

Electrodes shorting

Tank fills with electrode

Replace electrode assembly. If no

 

to ground.

wire disconnected from

remedy, check for improper wiring

 

 

 

“HI” terminal.

(cut insulation) or electrode tips

 

 

 

 

touching metal.

 

 

 

 

 

 

8)

Dual Level Control

Tank does not fill with

Replace Dual Level Control.

 

faulty.

electrode wire

 

 

 

 

disconnected from

 

 

 

 

“HI” terminal.

 

 

 

 

 

D) Auto Refill is erratic.

1) Electrode shorting to

Tank fills with electrode

Replace electrode assembly.

 

ground completely or

wire disconnected from

 

 

intermittently.

“HI” terminal.

 

 

 

 

 

 

 

2)

Loose connection.

Visual. Check “C” and

Push wire lead connector securely

 

 

 

“HI” probe terminals as

onto terminal(s). Replace connector

 

 

 

well as “FILL”. Also

if wire is frayed or broken.

 

 

 

check neutral (white)

 

 

 

 

wire at valve.

 

 

 

 

 

 

 

3)

Dual Level Control

Tank does not fill with

Replace Dual Level Control.

 

faulty.

electrode wires discon-

 

 

 

 

nected from “XL” and

 

 

 

 

“H” terminals.

 

IV) Trouble Shooting Auto Refill, Low Water Cutoff, and Dual Level Control System (continued)

Image 14
Contents High Speed Brewing Urn Top Line General Description American Metal Ware 87710E Coffee Urn Installation Operation Start-Up Checks/Brew Cycle Adjustments Spray-Over Time Volume RateTimer Adjustment How To Brew In An Automatic Urn Explanation Of Brewing CycleThermostat Thermostat AdjustmentPush Button Timer For Spray Over Control Spray Rinse Of LinerCare and Cleaning of Coffee Urn Semi-Weekly Cleaning ProcedureManual Agitation Automatic Program End of Brew and Delayed TypesSolid State Coffee Agitation System Operation Malfunction and Service Dual Level Control Auto Refill And Low Water Cutoff System OFF Metal American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffee Urn Service/Troubleshooting Solid State Air Agitation 53.20.10 Installation and Service InstructionsInstallation Alco Controls Division Emerson Electric Co 093-011 American Metal Ware 87710E Coffee Urn List of Illustrated Parts Steam Heat Only 87710E PartsElectric Heat Only American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffe Urn