Service/Troubleshooting Solid State Air Agitation
A vibrator air pump is located in the control box. This pump supplies the air to the coffee liners. It is turned on directly by pushing the manual agitation switch, and automatically by the brew timer or solid state relay in series with the brew timer.
The manual agitation switch is a momentary contact, normally open single pole black push button switch. Depressing the button closes the switch contacts completing the circuit to the air pump. It is wired parallel to the automatic agitation circuit.
The automatic
The following trouble shooting guide assumes that internal wiring is correct and 120V AC power is provided.
1.IF COFFEE LEVEL DOES NOT RISE BACK IN GAUGE GLASS, or is unusually slow to come back up, the very small vent hole in the clean out cap is clogged. Clear vent using a straight pin or similar object.
2.IF AGITATION DOES NOT STOP, check for sticking manual agitation switch. Where automatic agitation is built into timer, and manual switch checks okay, timer is defective and should be replaced. Where automatic agitation is a separate solid state agitation relay and manual switch checks okay, the relay is defective and should be replaced. If there is a constant “low” air pump output, the solid state timer or relay is defective and should be replaced.
3.IF NO AIR ENTERS LINER, check output of pump through outlet fittings on urn front. If okay, then make sure all connections are tight. Check for leaks at gauge glass, at top, bottom and at cleanout cap. May require new
4.IF LITTLE OR NO AIR COMES THROUGH FITTINGS ON URN FRONT, open control box and check pump operation. If pump operates, but has weak output, replace it. If air pump is okay, air lines between control box and front fittings are blocked or leak. Blockage usually is caused by overfilling liners. Use stiff thin wire to clear. If air lines leak, coffee liners are removed first, then tighten compression fittings at each end of lines.
5.IF NEITHER AUTOMATIC NOR MANUAL AGITATION OPERATES PUMP, pump is most likely defective and should be replaced.
6.IF AUTOMATIC AGITATION IS OKAY, BUT MANUAL DOES NOT WORK, replace manual agitation switch.
7.IF MANUAL AGITATION WORKS, BUT AUTOMATIC DOES NOT, replace the solid state brew timer or separate solid state agitation relay.
|
|