Disassembly

Disassemble in the same general order as indicated in exploded - view illustrations except as noted in the following steps:

1.De-pressurize valve and disconnect electrical power source.

2.To remove solenoid coil:

Insert small screwdriver into gap in voltage nameplate. Slide screwdriver tip under coil retainer and snap off. If replacing coil, use knife to separate adhesive-backed valve nameplate from coil. Keep valve nameplate.

3.To remove collar, use service tool X11981-1 shown in Figure 1

Note: Do NOT lose nameplate, as it is extremely important if it becomes necessary to order a parts kit, coil or duplicate valve.

Assembly

1.Assemble in the reverse general order of disassembly.

2.Lubricate gasket and “O” ring sparingly with a compatible lubricant such as a Silicon base lubricant.

3.All moving parts must move freely over the full length of its intended travel.

Troubleshooting

1.Check system fuses, electrical wiring and system source voltage as specified.

2.Is flow direction arrow on valve the same as system flow direction?

Cleaning

As with all valves, it may become necessary to clean them periodically to keep them in peak operating condition. Any cleaning methods or fluids used should be compatible with valve materials.

Inspection

1.All moving parts and elastomers should be clean in appearance without permanent set; springs should be free of corrosion. If any appear damaged, replace them with a parts kit which contains all moving parts necessary to rebuild valve to an “as new” condition.

2.Inspect enclosing tube assembly for wear, exterior dents or other conditions which would impair free movement of the poppet and/or plunger assembly. Its interior should be clean and free from any obstructions. Be especially critical of its valve seat.

Testing

1.Apply correct voltage to valve solenoid and cycle solenoid several times. A distinct click should be heard each time the solenoid is energized.

2.Pressurize valve and check for leaks.

Note: Alco solenoid valves are equipped with a continuous-duty solenoid coil, which when energized for an extended period of time becomes hot to the touch. This is a safe operating temperature. Any excessive heating will be indicated by smoke and odor of burning coil insulation.

3.Are all system relays operating?

4.Is system source pressure as specified?

5.Are all system components free from obstruction?

Repair Kits - The following Repair Kits are available.

Valve

Kit

Valve

Kit

Series

Part No.

Series

Part No.

202CB -B

K-1063

204CD -B

K-1072

202CB -F

K-1066

204CD -F

K-1075

202CB -N

K-1067

204CD -N

K-1073

202CB -P

K-1064

204CD -P

K-1076

202CB -T

K-1068

204CD -T

K-1077

202CB -V

K-1065

204CD -V

K-1074

 

 

 

 

 

 

Valve

Kit

 

 

Series

Part No.

 

 

For 1/4”

Or

ifice Only

 

 

204CD -B

K-1162

 

 

204CD -V

K-1164

 

 

204CD -T

K-1167

 

 

204CD -P

K-1166

 

Coils

1.Junction box (AMG) is supplied as standard on all valves.

2.The following coil housings are available:

a. Conduit Connection (AMC)

c. Open Frame (AMF)

b. GROMMET 18” Leads (AML)

d. Spade Connection (AMS)

3. Use only Alco coils on Alco valves.

Alco Controls Division • Emerson Electric Co.

P.O. Box 12700 • St. Louis, Missouri 63141 • 314-569-4500

Customer Service • 314-569-4666

 

 

American Metal Ware 87710E Coffee Urn

Page 19

Image 18
Contents High Speed Brewing Urn Top Line General Description American Metal Ware 87710E Coffee Urn Installation Spray-Over Time Volume Rate Timer AdjustmentOperation Start-Up Checks/Brew Cycle Adjustments How To Brew In An Automatic Urn Explanation Of Brewing CycleThermostat Thermostat AdjustmentPush Button Timer For Spray Over Control Spray Rinse Of LinerCare and Cleaning of Coffee Urn Semi-Weekly Cleaning ProcedureAutomatic Program End of Brew and Delayed Types Solid State Coffee Agitation SystemManual Agitation Operation Malfunction and Service Dual Level Control Auto Refill And Low Water Cutoff System OFF Metal American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffee Urn Service/Troubleshooting Solid State Air Agitation Installation and Service Instructions Installation53.20.10 Alco Controls Division Emerson Electric Co 093-011 American Metal Ware 87710E Coffee Urn List of Illustrated Parts 87710E Parts Electric Heat OnlySteam Heat Only American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffe Urn