IV) Trouble Shooting Auto Refill, Low Water Cutoff, and Dual Level Control System (continued)
Problem |
| Possible Cause | Service Check | Remedy | ||
|
|
|
|
|
| |
E) Tank fills with water, | 1) | Thermostat off. | Visual. | Make sure knob is turned fully | ||
but heat does not come |
|
|
| clockwise. | ||
on. |
|
|
|
| ||
2) | Thermostat inopera- | Jumper across thermo- | Recalibrate thermostat. If no reme- | |||
|
| |||||
|
| tive or out of calibration. | stat terminals causes | dy, or thermostat does not cycle, | ||
|
|
|
| heat to come on. | replace. | |
|
|
|
|
|
| |
|
| 3) | Power relay or con- | Check for voltage | If correct voltage, replace coil or | |
|
| tactor inoperative. | (120V AC) across coil | entire device. If not correct voltage, | ||
|
|
|
| terminals. | check for loose wires, improper | |
|
|
|
|
| wiring or other cause. | |
|
|
|
|
|
| |
|
| 4) | Low electrode faulty | Jumper from “XL” termi- | Clean electrodes. Check wiring. If | |
|
| or covered with lime | nal to metal enclosure | still no remedy, replace electrode | ||
|
| scale. | allows unit to heat. | assembly. | ||
|
|
|
|
|
| |
|
| 5) | Dual Level Control | Jumper from “XL” termi- | Replace Dual Level Control. | |
|
| faulty. | nal to “C” does not |
| ||
|
|
|
| cause unit to heat |
| |
|
|
|
|
|
| |
F) No water in tank, but | 1) | Thermostat and fill | Visual | Thermostat (brown wire) must be | ||
heat comes on (heater | valve connected to |
| connected to “HEAT” and fill valve | |||
damage likely). | wrong terminals on |
| (black wire) to “FILL”. | |||
|
| Dual Level Control. |
|
| ||
|
|
|
|
|
| |
|
| 2) | Electrode(s) shorting | Disconnecting wire | Replace electrode assembly. If no | |
|
| to ground. | (white) from “C” probe | remedy, check for improper wiring | ||
|
|
|
| terminal provides low | (cut insulation for instance), or elec- | |
|
|
|
| water heat cutoff and | trode tips touching metal inside tank. | |
|
|
|
| tank fill. |
| |
|
|
|
|
|
| |
|
| 3) | Dual Level Control | Heat comes on with no | Replace Dual Level Control. | |
|
| faulty. | probe wires (HI, XL, C) |
| ||
|
|
|
| connected |
| |
|
|
|
|
|
|