Grindmaster 87710 Thermostat Adjustment, Push Button Timer For Spray Over Control

Page 7

Thermostat

The thermostat is factory set so that the knob on the BREW setting holds the urn at brewing temperature toward the HI end of brew zone on the thermometer dial. Then, if turned back to HOLD position, the thermostat should cycle on and off and hold at the LO end of the BREW zone on the thermometer.

Thermostat Adjustment

1.If the water temperature is below the HI end of the BREW zone on the thermometer dial with the knob on BREW setting, remove the knob by pulling it straight outward. Using a small screwdriver, insert in the hole in the center of the shaft, turn slotted screw counter- clockwise until the red pilot light goes on. Check to see that water in the urn holds at the HI end of the BREW zone on the thermometer and does not boil.

2.If the water boils with the thermostat knob set at the BREW position, remove the knob by pulling it straight outward. Using a small screwdriver, insert into the hole in the center of the shaft, turn slotted screw clockwise until the red pilot light goes out. Hold shaft so it does not turn while adjusting screw. Add cold water and check that the heat comes back on (pilot light glows), and that the thermostat cycles at temperature at HI end of the BREW zone on thermometer dial.

If the thermostat will not cycle, replace the entire control.

Push Button Timer For Spray Over Control

The function of the timer is to start the pump and run it for a preset period of time and upon lapse of this time, to stop the pump, thereby completing the spray over cycle.

This urn is equipped with an electric reset timer. Pushing in the START button will start the flow of water. The timer will complete the time cycle for which it has been programmed and on completion, the flow will be stopped and the timer will reset itself, ready for the next brewing cycle.

If electric power is cut off anywhere in the service coming to the urn during the timer operating cycle, the timer will reset. When the power is restored, the timer must be restarted by pushing the START button.

Spray Rinse Of Liner

To rinse the liner after brewing coffee, swing the spray arm over the desired liner and push START button. Allow hot water to spray from the spray arm for approximately 30 to 60 seconds and then push STOP button and drain the liner.

 

 

Page 8

American Metal Ware 87710E Coffee Urn

Image 7
Contents High Speed Brewing Urn Top Line General Description American Metal Ware 87710E Coffee Urn Installation Timer Adjustment Spray-Over Time Volume RateOperation Start-Up Checks/Brew Cycle Adjustments Explanation Of Brewing Cycle How To Brew In An Automatic UrnSpray Rinse Of Liner Thermostat AdjustmentPush Button Timer For Spray Over Control ThermostatSemi-Weekly Cleaning Procedure Care and Cleaning of Coffee UrnSolid State Coffee Agitation System Automatic Program End of Brew and Delayed TypesManual Agitation Operation Malfunction and Service Dual Level Control Auto Refill And Low Water Cutoff System OFF Metal American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffee Urn Service/Troubleshooting Solid State Air Agitation Installation Installation and Service Instructions53.20.10 Alco Controls Division Emerson Electric Co 093-011 American Metal Ware 87710E Coffee Urn List of Illustrated Parts Electric Heat Only 87710E PartsSteam Heat Only American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffe Urn