Grindmaster 87710 service manual How To Brew In An Automatic Urn, Explanation Of Brewing Cycle

Page 6

How To Brew In An Automatic Urn

1.Place filter in brew basket with designated amount of ground coffee (automatic urns are designed to use 1, 2, 3 or 4 lbs. of coffee). Make certain you have a level bed of coffee. Consult your coffee supplier for exact brewing specifications. (C.B.C. recommendation is 1 lb. of coffee to each 2 1/2 gallons water).

2.Replace cover and move spray head over center of coffee grounds.

3.Check thermometer to make certain urn is at brewing temperature. Press timer button.

4.When brew cycle is completed (brew light shuts off), remove brew basket and dispose of spent grounds.

5.Mixing of finished brew is accomplished automatically at the end of the brew cycle if the urn has an air agitation option. Additional mixing can be performed at later time by pressing manual air agitation push button.

Where urn is not equipped with air agitation, draw one gallon for each three gallons of finished brew from coffee faucet, and pour over top into coffee liner.

The coffee is ready to serve.

6.Hold coffee at 185O - 190O F. or HOLD setting on thermostat knob. Brewed coffee can be held at this temperature for up to one hour with minimal deterioration of flavor and body.

Explanation Of Brewing Cycle

1.When timer button is pushed, the timer is activated.

2.The timer completes the circuit to the sprayover pump which delivers hot water through the spray arm to the spray nozzle.

3.The hot water from the spray nozzle is sprayed over the coffee grounds. The finished brew collects in the coffee liner.

4.As the pump delivers hot water from the water compartment through spray nozzle into brew basket, the water level in the water compartment lowers.

5.Drop in water level in water compartment below sensing probes activates liquid level control which opens the refill solenoid valve, refilling the water compartment with cold water.

6.The entry of the cold water activates the thermostat, which allows power to go to the heating element to maintain the brewing temperature

NOTE: Some urns may be equipped with an optional adjustable bypass valve on the spray arm. Adjustment of this valve will allow some spray water to bypass the brewing basket for additional control of the water/coffee brewing formula and the extraction percentage from the coffee.

 

 

American Metal Ware 87710E Coffee Urn

Page 7

Image 6
Contents High Speed Brewing Urn Top Line General Description American Metal Ware 87710E Coffee Urn Installation Spray-Over Time Volume Rate Timer AdjustmentOperation Start-Up Checks/Brew Cycle Adjustments How To Brew In An Automatic Urn Explanation Of Brewing CycleThermostat Thermostat AdjustmentPush Button Timer For Spray Over Control Spray Rinse Of LinerCare and Cleaning of Coffee Urn Semi-Weekly Cleaning ProcedureAutomatic Program End of Brew and Delayed Types Solid State Coffee Agitation SystemManual Agitation Operation Malfunction and Service Dual Level Control Auto Refill And Low Water Cutoff System OFF Metal American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffee Urn Service/Troubleshooting Solid State Air Agitation Installation and Service Instructions Installation53.20.10 Alco Controls Division Emerson Electric Co 093-011 American Metal Ware 87710E Coffee Urn List of Illustrated Parts 87710E Parts Electric Heat OnlySteam Heat Only American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffee Urn American Metal Ware 87710E Coffe Urn