installing your dryer
3-WIRE system connections
1.Loosen or remove the center terminal block screw.
2.Connect the neutral wire (white or center wire) of the power cord to the center,
3.Connect the other wires to outer terminal block screws. Tighten screws.
4.Tighten the strain relief screws.
5.Insert the tab of the terminal block cover into your dryer’s rear panel slot.
Secure the cover with a
b. Neutral grounding wire (green/yellow)
c. Center
e. 3/4” (1.9 cm)
If converting from a
block support to ground the dryer frame to the neutral conductor.
1.Remove the center terminal block screw.
2.Connect the ground wire (green or unwrapped) of the power cord to the external ground conductor screw.
3.Connect the neutral wire (white or center wire) of the power cord and the appliance ground wire (green with yellow stripes) under the central screw of the terminal block.
4.Connect the other wires to the outer terminal block screws. Tighten screws.
5.Tighten the strain relief screws.
6.Insert the tab of the terminal block cover into your dryer’s rear panel slot.
Secure the cover with a
b. Green or bare copper wire of power cord c. 3/4 in. (1.9 cm)
d. Center
f. Neutral wire (white or center wire)
5.With a level, check your dryer and make necessary adjustments to the leveling legs.
6.At this time, make sure all exhaust and electrical connections are complete. Plug in your dryer, and check operation by using the checklist below.
FINAL INSTALLATION CHECKLIST
Dryer is plugged into electrical outlet and properly grounded.
Exhaust ductwork is hooked up and joints taped.
Plastic flexible duct is NOT used.
Used rigid or
Dryer is level with all legs firmly on the floor.
Start your dryer to confirm that it runs, heats, and shuts off.
14_ Installing your dryer