Samsung DV665J user manual Final Installation Checklist, Wire system connections

Page 14

installing your dryer

3-WIRE system connections

1.Loosen or remove the center terminal block screw.

2.Connect the neutral wire (white or center wire) of the power cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.

3.Connect the other wires to outer terminal block screws. Tighten screws.

4.Tighten the strain relief screws.

5.Insert the tab of the terminal block cover into your dryer’s rear panel slot.

Secure the cover with a hold-down screw. a. External ground connector

b. Neutral grounding wire (green/yellow)

c. Center silver-colored terminal block screw d. Neutral wire (white or center wire)

e. 3/4” (1.9 cm) UL-listed strain relief

If converting from a 4-wire electrical system to a 3-wire, WARNING the ground strap must be reconnected to the terminal

block support to ground the dryer frame to the neutral conductor.

4-WIRE system connections

1.Remove the center terminal block screw.

2.Connect the ground wire (green or unwrapped) of the power cord to the external ground conductor screw.

3.Connect the neutral wire (white or center wire) of the power cord and the appliance ground wire (green with yellow stripes) under the central screw of the terminal block.

4.Connect the other wires to the outer terminal block screws. Tighten screws.

5.Tighten the strain relief screws.

6.Insert the tab of the terminal block cover into your dryer’s rear panel slot.

Secure the cover with a hold-down screw. a. External ground connector

b. Green or bare copper wire of power cord c. 3/4 in. (1.9 cm) UL-listed strain relief

d. Center silver-colored terminal block screw e. Grounding wire (green/yellow)

f. Neutral wire (white or center wire)

5.With a level, check your dryer and make necessary adjustments to the leveling legs.

6.At this time, make sure all exhaust and electrical connections are complete. Plug in your dryer, and check operation by using the checklist below.

FINAL INSTALLATION CHECKLIST

Dryer is plugged into electrical outlet and properly grounded.

Exhaust ductwork is hooked up and joints taped.

Plastic flexible duct is NOT used.

Used rigid or stiff-walled flexible metal vent material.

Dryer is level with all legs firmly on the floor.

Start your dryer to confirm that it runs, heats, and shuts off.

14_ Installing your dryer

Image 14
Contents Electric Dryer Features Important Safety Symbols and Precautions Safety instructionsWhat YOU Need to Know about Safety Instructions Property damageSafety instructions Safety instructions Contents Installing your dryer Installing your dryerTools Needed for Installation See Exhaust RequirementsRecommended Maximum Length Ducting RequirementsExhaust Length Calculation Electric DryersExhaust Directions Exhaust Duct Locating DimensionsImportant to Installer Stacking kit Model noSK-2AExhausting Alcove or Closet InstallationLocation Considerations United StatesGrounding Have a proper outlet installed by a qualified electricianElectrical Requirements Electric modelsElectric models U.S. only Replacement Parts and AccessoriesElectrical Connections Electric models Canada OnlyInstallation ModelsFinal Installation Checklist Wire system connectionsDon’t let a poor exhaust system slow drying by Inspect and clean the exhaust system annuallyDryer Exhaust Tips Door Reversal Operating Instructions, tips Overview of the Control PanelLoading Clothes HOW to Operate Your DryerPolyester Knits & Permanent Press Drying Tips Drying TimesCycle Chart Cycle Selecting GuideGetting Started Clean the Lint FilterLoad the Dryer Properly Care and cleaning Problem Possible Cause TroubleshootingQUESTIONS? USE this Problem Solver Code Symbol Meaning SolutionWash Cycle Special Instructions Laundering Fabric Care ChartAppendix Specifications Protecting the EnvironmentWarranty Samsung Dryer Limited Warranty to Original PurchaserWarranty Memo Code No. DC68-02369EEN Secadora eléctrica Gracias por comprar un producto SamsungCaracterísticas Símbolos Y Precauciones DE Seguridad Importantes Instrucciones de seguridadLO QUE Necesita Saber Sobre LAS Instrucciones DE Seguridad Este o de cualquier otro electrodomésticoInstrucciones de seguridad Instrucciones de seguridad Contenido Instalación DE LA SecadoraConsulte LOS Requisitos Para EL Drenaje Instalación de la secadoraHerramientas Necesarias Para LA Instalación Panel de control PuertaRequisitos Para EL Tendido DE Conductos Tabla 1 Longitud Máxima Recomendada Cálculo DE LA Longitud DEL DrenajeInstrucciones Sobre EL Drenaje Secadoras EléctricasConsideraciones Acerca DE LA Ubicación Dimensiones DE LA Ubicación DEL Conducto DE DrenajeImportante Para EL Instalador Kit de apilamiento Modelo Nro. SK-2AConexión a Tierra DrenajeRequisitos Eléctricos Modelos eléctricosModelos eléctricos Sólo EE.UU Conexiones EléctricasReemplazo DE LAS Piezas Y LOS Accesorios Modelos eléctricos Sólo CanadáInstalación Modelos EstadounidensesConexiones de sistemas de 3 Cables Conexiones de sistemas de 4 CablesLista DE Verificación Final DE LA Instalación Sugerencias Acerca DEL Drenaje DE LA Secadora Inversión DE LA Puerta Descripción General DEL Panel DE Control Botón Start Lámpara FilterFiltro PausaCómo Utilizar LA Secadora Para Secar LAS Prendas Usando LOS Ciclos DE SecadoCarga DE Ropa Tiempos DE SecadoAlgodón Guía DE Selección DE CicloProgramas Tipo de ropa Ejemplo de SinTabla DE Ciclos Cómo Comenzar Limpie EL Filtro Para PelusasCargue LA Secadora Apropiadamente Cuidado y limpieza Problema Causa Posible Solución de problemas¿PREGUNTAS? USE Esta Guía Para Solucionar Problemas Símbolo DEL Significado Solución Código Técnico. Consulte más abajoPlancha ApéndiceTabla Deindicaciones Sobre Latela Protección DEL Medio Ambiente Garantía SamsungGarantía Código Nº. DC68-02369EMES