Maytag MAT12PRD, MAT12PSB, MAT12PRB, MAT12PRA, MAT12PDS, MAT12PSA Pump, Drive Motor and Motor Base

Page 29

Disassembly Procedures

!WARNING

Pump

1.Disconnect power supply to unit.

2.Remove Front Panel.

3.Disconnect hoses from pump.

4.Tape washer lid to Top Cover.

5.Tilt washer and remove Pump Belt.

6.Remove three screws from bottom of base holding pump to base. The mounting holes for the pump on the base frame are slotted for adjustment of the Pump Belts.

Note: Mark the general position of pump before removing.

7. Tilt pump and lift through access hole in base frame.

Drive Motor and Motor Base

1.Disconnect power supply to unit.

2.Remove Front Panel.

To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.

3.Remove Motor Cover.

4.Remove main wiring harness from motor terminals.

Note: DO NOT remove the wires going from motor switch to motor.

5.Remove Belts.

6.Remove three screws holding motor base to base frame.

7.Remove Motor and Motor Base.

8.Remove Pulley from Motor.

9.Disengage tension springs and remove mounting nuts.

Note: To remove two of the nuts, align upper and lower sections and insert wrench through the slots into lower section.

10. Lift Motor Base off Motor.

Note: With Motor removed, carriage and slides are accessible for service.

©2003 Maytag Appliances Company

16022842 Rev. 0

29

Image 29
Contents Service Important Information Recognize Safety Symbols, Words, and LabelsTable of Contents Important Safety Information About Ground Wires Electrical Service InformationRelated Publications Proper Grounding and Polarization of 120 Volts Wall OutletsExplanation Grounding InstructionsParts and Accessories ServiceGeneral Information Model IdentificationHOW IT Works Water Level Control Pressure SwitchFill Water Valve Non-ThermostaticTransmission Drive MotorHelical Drive Spin cycle completedPart Number Description Tools for ServicingMechanical Troubleshooting Troubleshooting ProceduresDamper Pad Noise Drive Lug AdjustmentPump Belt Adjustment Electrical Troubleshooting Motor Testing Component TestingAgitation Spin Windings Wiring Harness Connections ReadingsCS Coin Slide Model Timer MN Manual Model TimerControl Panel Control Board MicroprocessorTouch pad Cycle Selector SwitchTransformer Motor Run RelayIndicator Light Timer models Lid Switch Assembly After seriesLid Switch Assembly Prior series Reversing Motor RelayUnbalance Lever and Plunger Assembly Pressure SwitchReinstalling Lid Switch Air DomeCoin Slide Water ValveCoin Drop Acceptor Meter CaseCoin Vault Switch Service Door SwitchReinstalling the Lid Coin SensorFront Panel Tub CoverBalance Ring Top CoverAgitator Access PlugInner Tub Tub CenteringMounting Stem Reinstalling Mounting StemOuter Tub Tub BearingTransmission Reinstalling tub bearingLip Seal Reinstalling Lip SealBrake Package and Radial Bearing Damper AssemblyBelts Drive Pulley and Rotor BearingDrive Motor and Motor Base Pump