Disassembly Procedures

!WARNING

Reinstalling Lid Switch

1.Insert the lid switch assembly in the Top Cover (Push the switch assembly straight down and back until it locks in place).

WRONG!

To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.

Pressure Switch

1.

Disconnect power supply to unit.

2.

Remove Control Panel.

3.

Disconnect wires attached to the switch.

4.

Remove clamp securing Air Dome Hose.

5.

Remove two screws securing Pressure Switch to the

Front Of Machine

Top

Cover

Top Cover.

RIGHT!

Top

Front OfCover

Machine

Unbalance Lever and Plunger Assembly

1.Disconnect power supply to unit.

2.Remove Lid and tilt the Top cover backwards.

3.Remove two screws securing the plunger assembly to the Top Cover.

Plunger Assembly

Air Dome

1.Disconnect power supply to unit.

2.Remove Control Panel and rear access service plate.

3.Remove clamp securing rubber hose to the Pressure Switch.

4.Remove clamp securing Air Dome to the Outer Tub spout.

Unbalance

Lever

©2003 Maytag Appliances Company

5.Disconnect rubber air tube secured to the cabinet.

6.Remove the air dome hose through the rear access opening.

16022842 Rev. 0

19

Image 19
Contents Service Important Information Recognize Safety Symbols, Words, and LabelsTable of Contents Important Safety Information Proper Grounding and Polarization of 120 Volts Wall Outlets Electrical Service InformationAbout Ground Wires Related PublicationsExplanation Grounding InstructionsModel Identification ServiceParts and Accessories General InformationWater Valve Non-Thermostatic Water Level Control Pressure SwitchHOW IT Works FillSpin cycle completed Drive MotorTransmission Helical DrivePart Number Description Tools for ServicingMechanical Troubleshooting Troubleshooting ProceduresPump Belt Adjustment Drive Lug AdjustmentDamper Pad Noise Electrical Troubleshooting Motor Testing Component TestingAgitation Spin Windings Wiring Harness Connections ReadingsControl Board Microprocessor MN Manual Model TimerCS Coin Slide Model Timer Control PanelMotor Run Relay Cycle Selector SwitchTouch pad TransformerReversing Motor Relay Lid Switch Assembly After seriesIndicator Light Timer models Lid Switch Assembly Prior seriesAir Dome Pressure SwitchUnbalance Lever and Plunger Assembly Reinstalling Lid SwitchMeter Case Water ValveCoin Slide Coin Drop AcceptorCoin Sensor Service Door SwitchCoin Vault Switch Reinstalling the LidTop Cover Tub CoverFront Panel Balance RingTub Centering Access PlugAgitator Inner TubTub Bearing Reinstalling Mounting StemMounting Stem Outer TubTransmission Reinstalling tub bearingLip Seal Reinstalling Lip SealBrake Package and Radial Bearing Damper AssemblyBelts Drive Pulley and Rotor BearingDrive Motor and Motor Base Pump