Disassembly Procedures
!WARNING
Coin Sensor
1.Disconnect power supply to unit.
2.Remove Control Panel and disconnect Coin Sensor connector plug on the Control Board.
3.Unlock service access door.
4.Remove Coin Drop Acceptor.
Service Door Switch
1.Disconnect power supply to unit.
2.Remove Service Access Door.
3.Remove the screw securing the switch mounting bracket and lift the switch from inside the Meter Case.
4.Disconnect wires from the switch, and squeeze tabs on switch to remove from bracket.
To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.
Lid
1.Disconnect power supply to unit.
2.Raise the lid where it is at a 45 degree angle.
3.With the left hand, grasp the left side of the lid toward the back. With the right hand, grasp the right side of the lid at the front right corner.
4.Taking care to watch the right hinge ball, pull towards you with the right hand. When the lid is disengaged from the right side of the top cover, catch the right hinge ball, remove the lid and catch the left hinge ball.
Reinstalling the Lid
1.Place a hinge ball in the recess of the left side of the top cover. Holding it in position, place the lid over the ball so the ball is in the recess on the left side of the lid.
Coin Vault Switch
1.Disconnect power supply to unit.
2.Remove Service Access Door and Coin Box.
3.Disconnect wires from the switch.
4.Squeeze the two tabs on the switch and push the switch through towards the front.
2.Hold the lid with the left hand as shown, keeping sufficient pressure against the left side to ensure the hinge ball will remain wedged between the lid and the top cover.
3.With the right hand , place a hinge ball in the right side of the Top Cover recess.
4.Push the lid down against the hinge ball on the right side and with the right thumb. Press down sharply to engaged the lid with the hinge ball on the right side.