General Information

HOW IT WORKS

The cycles are made up of three basic operations Fill, agitate and drain/spin. These operations are sequenced by the controls (timer or microprocessor board) to provide a proper cleaning cycle for each of several different fabrics.

FILL

Pressurized hot and cold water supplies are required. The dynamic, or flow pressure should be between 30 lbs. per square inch and 80 lbs. per square inch (p.s.i.). Pressure below 20 lbs p.s.i. may cause water line hammering.

Hot water is describe to be 140° F and cold water temperature should be 75° F. A 50-50 mix of hot water and cold should result in warm temperature between 100° F and 105° F.

The components involved in a fill operation are the water valve assembly, the water level control and the timer or control board. The control board or timer along with the selector switch tell the valve whether to allow hot, cold or both (warm) into the washer. The water level control (a.k.a. pressure switch) controls the level of the water in the washer. It should be at the top row of holes (perforations) in the washer basket plus or minus 1/4 inch.

Water Valve (Non-Thermostatic)

The water valve used on the top load washers is designed to operate with in a pressure range of 30-120 p.s.i.. Flow pressure cannot fall below 20 p.s.i. or valves may fail to close when solenoids are de-energized.

Water from source enters valve at inlet and pushes up on diaphragm. The solenoid plunger and the plunger spring are not strong enough to hold the diaphragm in a closed position. The diaphragm lifted and some water will flow under the diaphragm and into the outlet.

Some water also flows through bleeder holes in the diaphragm and into the guide tube area behind the diaphragm. With the solenoid not energized, the plunger would block the pressure release hole allowing the guide tube to pressurize to source pressure. This causes the diaphragm to be pushed against the valve seat blocking the valve seat and closing the outlet.

While there is equal pressure (source pressure) on both sides of the diaphragm, the pressure in the guide tube area covers a greater surface area of the diaphragm. The center (outlet area) on the bottom side of the diaphragm is at atmospheric pressure so the valve remains closed. It

is important to understand that water pressure is the operation force in the water valve.

When the valve operating solenoid is energized, a magnetic field is produced that lifts the plunger away from the pressure release hole in the center of the diaphragm. The pressure in the guide tube area is released through the hole allowing the inlet pressure to lift the diaphragm off of the outlet seat. Water flows under the diaphragm and out through the valve outlet.

Because the bleed holes cannot allow water into the guide tube area as rapidly as it can escape out through the pressure release hole, the diaphragm will remain in the open position as long as the plunger is held away from the release hole.

When the plunger is released (solenoid coil de-energized), it again blocks the release hole allowing pressure entering though the bleed holes to again force the diaphragm back against the outlet seat, stopping the flow of water. A nozzle arrangement at the center of the diaphragm causes the valve closure to be gradual and smooth to reduce the chances of water hammer as the valve closes.

Water Level Control (Pressure Switch)

The water level switch is a single pole-double throw switch which is activated by air pressure increase against a sealed diaphragm. An air hose is connected to a spout at the bottom of the outer water container (outer tub) and to an inlet spout at the water level control body.

As water enters the tubs and the water level raises, air is trapped in the air dome at the bottom of the pressure switch hoses. As the water level increases, this air is pushed up the hose and against the diaphragm in the water level control body.

The control is designed to cause the contact points to switch when the water level in the wash basket (and the outer container) reach a particular level. At that point the fill circuits are disconnected and the motor circuit is energized. This corresponds to empty = fill and full = run.

Air leaks at the hose connections cannot be tolerated for proper operation of the water level control.

In timer models, a bypass circuit is provided by the timer and selector switch to continue power to the motor in spin operations. Without the bypass, the drive motor would stop when sufficient water had been pumped out of the washbasket to cause the pressure switch to reset to the ”empty” position. Microprocessor models do not need the bypass circuit.

8

16022842 Rev. 0

©2003 Maytag Appliances Company

Image 8
Contents Service Recognize Safety Symbols, Words, and Labels Important InformationTable of Contents Important Safety Information Electrical Service Information About Ground WiresRelated Publications Proper Grounding and Polarization of 120 Volts Wall OutletsGrounding Instructions ExplanationService Parts and AccessoriesGeneral Information Model IdentificationWater Level Control Pressure Switch HOW IT WorksFill Water Valve Non-ThermostaticDrive Motor TransmissionHelical Drive Spin cycle completedTools for Servicing Part Number DescriptionTroubleshooting Procedures Mechanical TroubleshootingDamper Pad Noise Drive Lug AdjustmentPump Belt Adjustment Electrical Troubleshooting Component Testing Motor TestingWindings Wiring Harness Connections Readings Agitation SpinMN Manual Model Timer CS Coin Slide Model TimerControl Panel Control Board MicroprocessorCycle Selector Switch Touch padTransformer Motor Run RelayLid Switch Assembly After series Indicator Light Timer modelsLid Switch Assembly Prior series Reversing Motor RelayPressure Switch Unbalance Lever and Plunger AssemblyReinstalling Lid Switch Air DomeWater Valve Coin SlideCoin Drop Acceptor Meter CaseService Door Switch Coin Vault SwitchReinstalling the Lid Coin SensorTub Cover Front PanelBalance Ring Top CoverAccess Plug AgitatorInner Tub Tub CenteringReinstalling Mounting Stem Mounting StemOuter Tub Tub BearingReinstalling tub bearing TransmissionReinstalling Lip Seal Lip SealDamper Assembly Brake Package and Radial BearingDrive Pulley and Rotor Bearing BeltsPump Drive Motor and Motor Base