LG Electronics D2532W, D5932W, D5911W, D2511W, DLE2511W manual Manufactured Mobile Home Installation

Page 11

MANUFACTURED (MOBILE) HOME INSTALLATION

IMPORTANT : Installation must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 32-80 or Standard CAN/CSA-Z240 MH.

Safety Instructions

The dryer can be installed in a manufactured (mobile) home by following these instructions:

1.IMPORTANT : Gas dryers MUST be permanently attached to the floor at the time of installation.

2 Electrical Connections (Electric Dryer Only) must be a

4-wire connection.

3 Venting - Dryer MUST be exhausted to the outdoors.

WARNING

To reduce the risk of fire and combustion gas accumulation, the dryer MUST BE EXHAUSTED TO THE OUTDOORS. Refer to Section on Dryer Exhaust Requirements.

The dryer can be exhausted to the outdoors through the back, left, right or bottom panel. Gas dryers cannot be exhausted out the right side because of the burner housing.

The dryer exhaust duct must be secured to the mobile home structure.

Exhaust ducts MUST NOT be connected with sheet metal screws or fasteners which extend into the duct.

Exhaust duct must not be connected to any other duct, vent or chimney.

Dryer exhaust duct MUST NOT terminate under the mobile home.

For proper operation, it is important that the dryer has an ample amount of outside Fresh air. The opening for outside air must be at least 25 in2 (163 cm2)

When exhausting the dryer to the outdoors, the dryer can be installed with “1” inch clearance at the sides and rear. Clearance of the duct from combustible construction must be a minimum of 2 inches

(5.08 cm).

Venting materials are not supplied with the dryer (obtain locally).

WARNING

To reduce the risk of fire, the exhaust duct and weather hood MUST be fabricated of a material that will not support combustion. Rigid or flexible metal pipe is recommended for a clothes dryer.

Installation Instructions Operating Instruction Troubleshooting Tips Customer Service

1 1

Image 11
Contents Electric and Gas Dryer Before Using Your NEW Dryer Table of ContentsWhat to do if YOU Smell GAS Important Safety Instructions Important Safety InstructionsRequirements LG Dryer WarrantyInstallation Installation InstructionsInstallation clearances Minimum installation spacing for a recessedConnect Dryer Exhaust System Installing the DryerFailure to exhaust dryer properly will void warranty Position and Level the DryerRequirements Connect Gas Supply Pipe Gas Dryer onlyHeat Source Check Door Reversal Procedure Manufactured Mobile Home Installation Grounding Instructions Electrical Requirements Electrical DryerWire connection Direct wire Wire connection Power supply cord12.7cm Wire connection Direct wire Electrical Requirements GAS Dryer Grounding Instructions Supply line requirements GAS RequirementsExhaust System Exhaust RequirementsExhaust System Materials Maximum length of 4 10.2 cm diameter flexible metal duct Maximum length of 4 10.2 cm diameter rigid metal ductDryer Airflow Exhaust System MaintenanceCleaning the Lint Screen User MaintenanceFeatures and Benefits Fire Hazard No washer can completely remove oil Starting Your DryerStopping Your Dryer Pausing or RestartingTo use a Sensor Dry Cycle To use a Manual Dry CycleCycle Descriptions Options ModifiersTo recall your stored Custom Program To use the Rack DRYTo store a Custom Program Problem Possible Causes What To Do Before YOU Call for ServiceService Telephone Numbers LG Dryer Limited Warranty USA