3-wire connection: Direct wire

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.

Strip 3V2 in. (8.9 cm) of outer covering from end of cable. Strip insulation back 1 in. (2.5 cm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw.

1" .5cm) (2

3V2" (8.9cm)

1. Loosen or remove center terminal block screw.

2. Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.

1

3

4

2

5

1.External ground connector

2.Neutral grounding wire (green)

3.Center silver-colored terminal block screw

4.Neutral wire (white or center wire)

5.3/4 in. (1.9 cm) UL-listed strain relief

3. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

4. Tighten strain relief screws.

5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

Optional 3-wire connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

1. Remove center terminal block screw.

2. Remove appliance ground wire (green) from external ground connector screw. Connect appliance ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver colored terminal block screw. Tighten screw.

3. Connect the other wires to outer terminal block screws. Tighten screws.

4. Tighten strain relief screws.

5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

6. Connect a separate copper ground wire from the external ground connector screw to an adequate ground.

1

2

3

4

1.External ground connector

2.Neutral grounding wire (green)

3.Neutral wire (white or center wire)

4.Grounding path determined by a qualified electrician

Safety Instructions Installation Instructions Operating Instruction Troubleshooting Tips Customer Service

1 5

Image 15
Contents Electric and Gas Dryer Before Using Your NEW Dryer Table of ContentsWhat to do if YOU Smell GAS Important Safety Instructions Important Safety InstructionsRequirements LG Dryer WarrantyInstallation Installation InstructionsInstallation clearances Minimum installation spacing for a recessedConnect Dryer Exhaust System Installing the DryerFailure to exhaust dryer properly will void warranty Position and Level the DryerRequirements Connect Gas Supply Pipe Gas Dryer onlyHeat Source Check Door Reversal Procedure Manufactured Mobile Home Installation Grounding Instructions Electrical Requirements Electrical DryerWire connection Direct wire Wire connection Power supply cord12.7cm Wire connection Direct wire Electrical Requirements GAS Dryer Grounding Instructions Supply line requirements GAS RequirementsExhaust Requirements Exhaust System MaterialsExhaust System Maximum length of 4 10.2 cm diameter flexible metal duct Maximum length of 4 10.2 cm diameter rigid metal ductDryer Airflow Exhaust System MaintenanceCleaning the Lint Screen User MaintenanceFeatures and Benefits Fire Hazard No washer can completely remove oil Starting Your DryerStopping Your Dryer Pausing or RestartingTo use a Sensor Dry Cycle To use a Manual Dry CycleCycle Descriptions Options ModifiersTo use the Rack DRY To store a Custom ProgramTo recall your stored Custom Program Problem Possible Causes What To Do Before YOU Call for ServiceService Telephone Numbers LG Dryer Limited Warranty USA