Exhaust System Maintenance

The dryer interior and the complete exhaust system should be inspected after one year of use and cleaned if necessary. Inspect and clean exhaust duct every one to two years as required thereafter. The weather hood should be checked frequently to make sure the dampers move freely, they are not pushed in and that nothing has been set against them. This maintenance work should be done by a qualified service person.

WARNING

To reduce the risk of electric shock, disconnect the electrical power to the dryer before cleaning.

Exhausting the dryer in hard-to reach locations can be accomplished by installing the Flexible Metal Vent Kit, available as optional equipment at extra cost. The kit comes in two halves that can be separately attached to the dryer and wall outlet. Once attached, the dryer can be slid back into position and the two halves can be connected from the front.

Dryer Airflow

Efficient dryer operation requires proper dryer airflow. Proper dryer airflow can be evaluated by measuring the static pressure.

Static pressure in the dryer’s exhaust duct should be no greater than 0.6 inchs (1.5 cm). (Check with dryer running and no load.)

NOTE : This can be measured with a manometer placed on the exhaust duct approximately 2 ft. (61 cm) from the dryer.

 

MAXIMUM STATIC

 

PRESSURE IN

 

WATER COLUMN

 

0.6 inches (1.5 cm)

 

1

 

2

 

Measuring Static pressure

1

Manometer

2

Exhaust Duct

Figure 28

Safety Instructions Installation Instructions Operating Instruction Troubleshooting Tips Customer Service

2 1

Image 21
Contents Electric and Gas Dryer Before Using Your NEW Dryer Table of ContentsWhat to do if YOU Smell GAS Important Safety Instructions Important Safety InstructionsRequirements LG Dryer WarrantyInstallation clearances Installation InstructionsMinimum installation spacing for a recessed InstallationFailure to exhaust dryer properly will void warranty Installing the DryerPosition and Level the Dryer Connect Dryer Exhaust SystemRequirements Connect Gas Supply Pipe Gas Dryer onlyHeat Source Check Door Reversal Procedure Manufactured Mobile Home Installation Grounding Instructions Electrical Requirements Electrical DryerWire connection Direct wire Wire connection Power supply cord12.7cm Wire connection Direct wire Electrical Requirements GAS Dryer Grounding Instructions Supply line requirements GAS RequirementsExhaust Requirements Exhaust System MaterialsExhaust System Maximum length of 4 10.2 cm diameter flexible metal duct Maximum length of 4 10.2 cm diameter rigid metal ductDryer Airflow Exhaust System MaintenanceCleaning the Lint Screen User MaintenanceFeatures and Benefits Fire Hazard No washer can completely remove oil Starting Your DryerTo use a Sensor Dry Cycle Pausing or RestartingTo use a Manual Dry Cycle Stopping Your DryerCycle Descriptions Options ModifiersTo use the Rack DRY To store a Custom ProgramTo recall your stored Custom Program Problem Possible Causes What To Do Before YOU Call for ServiceService Telephone Numbers LG Dryer Limited Warranty USA