Exhaust System Maintenance
The dryer interior and the complete exhaust system should be inspected after one year of use and cleaned if necessary. Inspect and clean exhaust duct every one to two years as required thereafter. The weather hood should be checked frequently to make sure the dampers move freely, they are not pushed in and that nothing has been set against them. This maintenance work should be done by a qualified service person.
WARNING
To reduce the risk of electric shock, disconnect the electrical power to the dryer before cleaning.
Exhausting the dryer in
Dryer Airflow
Efficient dryer operation requires proper dryer airflow. Proper dryer airflow can be evaluated by measuring the static pressure.
Static pressure in the dryer’s exhaust duct should be no greater than 0.6 inchs (1.5 cm). (Check with dryer running and no load.)
NOTE : This can be measured with a manometer placed on the exhaust duct approximately 2 ft. (61 cm) from the dryer.
| MAXIMUM STATIC |
| PRESSURE IN |
| WATER COLUMN |
| 0.6 inches (1.5 cm) |
| 1 |
| 2 |
| Measuring Static pressure |
1 | Manometer |
2 | Exhaust Duct |
Figure 28
Safety Instructions Installation Instructions Operating Instruction Troubleshooting Tips Customer Service
2 1