ELECTRICAL REQUIREMENTS - ELECTRICAL DRYER

Customer Service Troubleshooting Tips Operating Instruction Installation Instructions Safety Instructions

Electric Dryers

(120V/240 Volt, 60 Hertz, 3-Wire Installation) (120V/208 Volt, 60 Hertz, 3-Wire Installation)

NOTE : The wiring diagram is located inside the control hood.

WARNING

To reducd the risk of fire, electric shock, serious injury or death, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses checked by a qualified electrician to make sure your home has adequate electrical power to operate the dryer.

Grounding Instructions

This dryer must be connected to a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.

The dryer has its own terminal block that must be connected to a separate branch, 60 Hertz, single phase circuit, AC (alternating current) circuit, fused at 30 Amperes (the circuit must be fused on both sides of the line). ELECTRICAL SERVICE FOR THE

DRYER SHOULD BE OF MAXIMUM RATE VOLTAGE LISTED ON THE NAMEPLATE. DO NOT CONNECT DRYER TO 110, 115, OR 120 VOLT CIRCUIT. Heating elements are available for field installation in dryers which are to be conected to electrical service of different voltage than that listed on nameplate, such as 208 Volt.

If branch circuit to dryer is fifteen feet (4.50 m) or less in length, use U.L. (Underwriters Laboratories) listed No. 10 A.W.G. wire (copper wire only), or as required by local codes. If over fifteen feet (4.50 m), use U.L. (Underwriters Laboratories) listed No. 8 A.W.G. wire (copper wire only), or as required by local codes. Allow sufficient slack in wiring so dryer can be moved from its normal location when necessary.

The power cord (pigtail) connection between wall receptacle and dryer terminal block IS NOT supplied with dryer. Type of pigtail and gauge of wire must conform to local codes and with instructions mentioned on the following pages.

The method of wiring the dryer is optional and subject to local code requirements. Refer to examples on next page.

1 2

Image 12
Contents Electric and Gas Dryer Table of Contents Before Using Your NEW DryerWhat to do if YOU Smell GAS Important Safety Instructions Important Safety InstructionsLG Dryer Warranty RequirementsInstallation Instructions Installation clearancesMinimum installation spacing for a recessed InstallationInstalling the Dryer Failure to exhaust dryer properly will void warrantyPosition and Level the Dryer Connect Dryer Exhaust SystemConnect Gas Supply Pipe Gas Dryer only RequirementsHeat Source Check Door Reversal Procedure Manufactured Mobile Home Installation Electrical Requirements Electrical Dryer Grounding InstructionsWire connection Power supply cord Wire connection Direct wire12.7cm Wire connection Direct wire Electrical Requirements GAS Dryer Grounding Instructions GAS Requirements Supply line requirementsExhaust Requirements Exhaust System MaterialsExhaust System Maximum length of 4 10.2 cm diameter rigid metal duct Maximum length of 4 10.2 cm diameter flexible metal ductExhaust System Maintenance Dryer AirflowUser Maintenance Cleaning the Lint ScreenFeatures and Benefits Starting Your Dryer Fire Hazard No washer can completely remove oilPausing or Restarting To use a Sensor Dry CycleTo use a Manual Dry Cycle Stopping Your DryerCycle Descriptions Modifiers OptionsTo use the Rack DRY To store a Custom ProgramTo recall your stored Custom Program Before YOU Call for Service Problem Possible Causes What To DoService Telephone Numbers LG Dryer Limited Warranty USA