Fisher & Paykel DEGX1US installation instructions Fitting the front feet

Page 15

Fitting the front feet

Note: Dryer is usually supplied with feet fitted and protruding the correct distance.

1.Tilt the dryer back using a hand trolley and making sure the trolley and dryer are secure.

2.Fit a rubber insert to each plastic foot as shown.

3. Screw the feet into the foot retainers on the left hand and right hand sides as shown.

4.Screw both feet in so they protrude ¹⁄” (12mm) below the bottom of the wall on the foot retainers.

15

Image 15
Contents Installation instructions Important safety instructions Parts supplied Read this before you start installing your dryerAccessories Tools requiredTo the installer Location requirementsExplosion Hazard Alcove or closet installation Dimensions Lid clearanceExhaust outlet location Mobile home installation Fire Hazard ExhaustingDetermine vent duct length Maximum length of exhaust duct Preferred 4 Hoods Alternative installation for close clearances Exhaust venting Remove packaging InstallationExcess Weight Hazard UnpackingFitting the front feet Electrical requirements Electric Shock Hazard208V Requirements Grounding for a permanently connected appliance Grounding instructionsElectrical Shock Hazard Grounding for a cord-connected applianceConnecting by direct wire Power supply cord requirements for U.S.AFor 4-wire connections by direct wiring For 3-wire connections by power cordsFor 3-wire connections by direct wiring For 4-wire connections by power cordsRemove the terminal block cover plate Wire connectionsWire connections plus separate grounding connector Wire connections Level machine Final installation check listInstallation Instructions Published 03/2004 Part No a