Fisher & Paykel DEGX1US Wire connections plus separate grounding connector

Page 21

3-wire connections plus separate grounding connector

For use where local codes do not permit grounding through the Neutral wire.

Use approved 3-wire Power Supply Cord or a 3-wire Cable for Direct Wiring as described on page 18. A separate 10AWG copper grounding wire is required.

1.Remove the terminal block cover plate.

2.Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet near the terminal block. Do not tighten strain relief screw until wiring connections are complete.

Note: a strain relief must be used.

2

strain relief clamp sections

strain relief screws

3.Remove center terminal block screw.

4.Remove appliance ground link by removing the ground connector screw (Green screw).

5.Connect a separate copper ground wire (green with yellow stripe) using the ground connector screw (Green screw). Make sure a ring terminal is used when connecting the ground wire and that the wire is firmly secured to an adequate grounding path.

3

7

6

4

5

 

7

6.Connect the neutral wire (center) of the power supply cord to the center terminal screw of the terminal block. Tighten screw.

7.Connect the other wires to the upper and lower terminal block screws marked with the letter L. Tighten screws.

8.Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and secure cover with securing screw.

9.Tighten strain relief screws.

8

9

grounding wire

It is recommended that a qualified electrician determine that the ground path is adequate

21

Image 21
Contents Installation instructions Important safety instructions Accessories Read this before you start installing your dryerTools required Parts suppliedTo the installer Location requirementsExplosion Hazard Alcove or closet installation Dimensions Lid clearanceExhaust outlet location Mobile home installation Fire Hazard ExhaustingDetermine vent duct length Maximum length of exhaust duct Preferred 4 Hoods Alternative installation for close clearances Exhaust venting Excess Weight Hazard InstallationUnpacking Remove packagingFitting the front feet Electrical requirements Electric Shock Hazard208V Requirements Electrical Shock Hazard Grounding instructionsGrounding for a cord-connected appliance Grounding for a permanently connected applianceConnecting by direct wire Power supply cord requirements for U.S.AFor 3-wire connections by direct wiring For 3-wire connections by power cordsFor 4-wire connections by power cords For 4-wire connections by direct wiringRemove the terminal block cover plate Wire connectionsWire connections plus separate grounding connector Wire connections Level machine Final installation check listInstallation Instructions Published 03/2004 Part No a