Fisher & Paykel DEGX1US Electrical connections, For 3-wire connections by power cords

Page 19

Electrical connections

Please read Electrical requirements and grounding instructions on pages 16–18 first.

The DEGX1 electric model of the SmartLoad™ dryer is manufactured for a 3-wire connection system. The dryer frame is grounded by a link to the neutral conductor on the dryer terminal block. If local codes do not permit grounding through the neutral, the grounding link from the terminal block must be removed and a separate ground wire must be used.

The grounding link on the dryer must be removed for all 4-wire installations including new, remodelled construction, or mobile homes.

These Electrical Connection instructions provide for installing the SmartLoad™ dryer in the following situations:

3-wire connection where local codes permit grounding through the neutral.

3-wire connection plus separate grounding connector where local codes do not permit grounding through the neutral.

4-wire connection.

Each of the above connections can be made with an approved power supply cord or by direct wiring. Each connection instruction identifies the appropriate Power Supply Cord & covers requirements for direct wiring.

For 3-wire connections by power cords

3-wire power supply cord must have three 10 AWG copper wires and match a 3-wire receptacle of NMEA Type10-30R.

For 3-wire connections by direct wiring

 

Three-wire with ground

 

wire: Bare wire cut short.

 

Wire not used. Dryer is

3/4UL-listed

grounded through neutral

strain relief

or separate grounding

 

to disconnect

 

box

 

10-gauge, 3-wire or,

41/4

10-gauge, 3-wire with

ground wire (Romex)

 

1” of wires stripped of insulation

NEUTRAL wire (white or center)

Strip 41/4” of outer covering from end of cable. Strip insulation back 1”. If using 3-wire cable with ground wire, cut bare wire even with outer covering.

Shape ends of wire into a hook.

For 4-wire connections by power cords

4-wire power supply cord must have four 10 AWG copper wires and match a 4-wire receptacle of NMEA Type14-30R. The fourth wire (ground conductor) must be identified by a green cover and the neutral wire by a white cover.

For 4-wire connections by direct wiring

 

41/4

3/4UL-listed

1” of wires

strain relief

stripped of

insulation

 

to disconnect

NEUTRAL wire

box

(white or center)

 

10-gauge, 3-wire with ground

bare ground wire

wire (Romex)

 

Strip 41/4” of outer covering from end of cable. Strip insulation back 1”.

Shape ends of wire into a hook.

19

Image 19
Contents Installation instructions Important safety instructions Parts supplied Read this before you start installing your dryerAccessories Tools requiredLocation requirements To the installerExplosion Hazard Alcove or closet installation Lid clearance DimensionsExhaust outlet location Mobile home installation Fire Hazard ExhaustingDetermine vent duct length Maximum length of exhaust duct Preferred 4 Hoods Alternative installation for close clearances Exhaust venting Remove packaging InstallationExcess Weight Hazard UnpackingFitting the front feet Electric Shock Hazard Electrical requirements208V Requirements Grounding for a permanently connected appliance Grounding instructionsElectrical Shock Hazard Grounding for a cord-connected applianceConnecting by direct wire Power supply cord requirements for U.S.AFor 4-wire connections by direct wiring For 3-wire connections by power cordsFor 3-wire connections by direct wiring For 4-wire connections by power cordsRemove the terminal block cover plate Wire connectionsWire connections plus separate grounding connector Wire connections Level machine Final installation check listInstallation Instructions Published 03/2004 Part No a