Fisher & Paykel DEGX1US Wire connections, Remove the terminal block cover plate

Page 20

3-wire connections

For use where local codes permit grounding through the Neutral wire.

Use approved 3-wire Power Supply Cord or a 3-wire Cable for Direct Wiring as described on page 18.

1.Remove the terminal block cover plate.

2.Insert the power cord with a UL listed strain relief through the hole provided in the cabinet near the terminal block. Do not tighten strain relief screw until wiring connections are complete.

Note: a strain relief must be used.

2

strain relief clamp sections

strain relief screws

3.Loosen or remove the center terminal block screw. Connect the neutral wire (center) of the power supply cord to the center terminal screw of the terminal block. Tighten screw.

4.Connect the other wires to the upper and lower terminal block screws marked with the letter L. Tighten screws.

Note: If the appliance is moved back to a 3-wire installation the ground link must be refitted.

4

3

4

5.Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer. Secure cover with securing screw.

6.Tighten strain relief screws.

5

6

20

Image 20
Contents Installation instructions Important safety instructions Read this before you start installing your dryer AccessoriesTools required Parts suppliedExplosion Hazard To the installerLocation requirements Alcove or closet installation Exhaust outlet location DimensionsLid clearance Mobile home installation Exhausting Fire HazardDetermine vent duct length Maximum length of exhaust duct Preferred 4 Hoods Alternative installation for close clearances Exhaust venting Installation Excess Weight HazardUnpacking Remove packagingFitting the front feet 208V Requirements Electrical requirementsElectric Shock Hazard Grounding instructions Electrical Shock HazardGrounding for a cord-connected appliance Grounding for a permanently connected appliancePower supply cord requirements for U.S.A Connecting by direct wireFor 3-wire connections by power cords For 3-wire connections by direct wiringFor 4-wire connections by power cords For 4-wire connections by direct wiringWire connections Remove the terminal block cover plateWire connections plus separate grounding connector Wire connections Final installation check list Level machineInstallation Instructions Published 03/2004 Part No a