Electrolux 134912700, EWMED65H, 137018200 A, 134709300 Gas connection, Todryer

Page 14

14Installation Instructions

Gas connection

1.Remove the shipping cap from gas pipe at the rear of the dryer.

IMPORTANT

DO NOT connect the dryer to L.P. gas service without converting the gas valve. An L.P. conversion kit must be installed by a qualified gas technician.

2.Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of the dryer. Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm) reducer for the connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections.

Manual

Flare

GAS FLOW

Flare

Shutoff

 

Union

 

Union

Valve

 

 

 

Closed

 

 

 

Nipple

Flexible

Inlet Pipe on

Open

 

Connector

Back of Dryer

All connections must be wrench-tightened

IMPORTANT

The supply line must be equipped with an approved manual shutoff valve. This valve should be located in the same room as the dryer and should be in a location that allows ease of opening and closing. Do not block access to the gas shutoff valve.

3.Open the shutoff valve in the gas supply line to allow gas to flow through the pipe. Wait a few minutes for gas to move through the gas line.

todryer

from

gas

supply

 

 

 

Shutoff Valve -

Open position

4.Check for gas system leaks with a manometer. If a manometer is not available, test all connections by brushing on a soapy water solution.

WARNING

EXPLOSION HAZARD

NEVER test for gas leaks with an open flame.

Image 14
Contents Installation Instructions Please read and save this guide Table of contentsFinding Information Keep a record for quick referencePre-installation requirements SafetyImportant Safety Instructions Wire receptacle Nema type 14-30R Installation RequirementsWire receptacle Nema type 10-30R Electrical system requirementsGas supply requirements Exhaust system requirementsInstall male fittings in correct direction Manufactured or mobile home installation Exhaust directionDo not Install Your Dryer Clearance requirementsInstalled dryer dimensions Grounding requirements Electric dryer USA Installation InstructionsElectrical installation Grounding requirements Electric dryer Canada Grounding requirements Gas dryer USA and CanadaElectrical connection non-Canada 3 wire cord Electrical connection non-Canada 4 wire cord Gas connection TodryerWater connection Steam Model only Water connection, con’t Steam Model only General installation Performing Installation Cycle Removing door and hardware Reversing DoorPreparing to reverse door swing Removing Trim RingReversing door Reversing Hardware on Front Panel Removing Door HardwareRemoving Latch Indicator Removing Hole Plug Reinserting Latch Indicator Reinserting Hole PlugReattaching Door to Front Panel Reattaching Latch PlateReattaching Hinge Reversing Trim Ring Reinstalling Trim RingReinstalling Trim Plug Plug in dryer and continue operationAccesories Replacement parts 1-877-4ELECTROLUXOptions