6Installation Requirements

Exhaust system requirements, continued

WARNING

FIRE HAZARD

A clothes dryer must be exhausted outdoors. Do not exhaust dryer into a chimney, a wall, a ceiling, an attic, a crawl space or any concealed space of a building. A clothes dryer produces combustible lint. If the dryer is not exhausted outdoors, some fine lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard.

The dryer must be connected to an exhaust outdoors. Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area.

WARNING

FIRE HAZARD

Do not allow combustible materials (for example: clothing, draperies/curtains, paper) to come in contact with exhaust system. The dryer MUST NOT be exhausted into a chimney, a wall, a ceiling, or any concealed space of a building which can accumulate lint, resulting in a fire hazard.

Do not screen the exhaust ends of the vent system, or use any screws, rivets or other fasteners that extend into the duct to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fire hazard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings MUST be installed downstream with the flow of air.

WARNING

FIRE HAZARD

Exceeding the length of duct pipe or number of elbows allowed in the “MAXIMUM LENGTH” charts can cause an accumulation of lint in the exhaust system. Plugging the system could create a fire hazard, as well as increase drying times.

 

 

MAXIMUM LENGTH

 

Number

of 4” (10.2cm) Rigid Metal Duct

 

VENT HOOD TYPE

 

 

(Preferred)

 

of 90°

 

 

 

turns

 

 

2.5”

4”

 

 

(10.2cm)

louvered

(6.35cm)

0

125 ft. (38.10m)

110 ft. (33.53m)

1

115 ft. (35.05m)

100 ft. (30.48m)

2

105 ft. (32.00m)

90 ft. (27.43m)

3

95 ft. (28.96m)

80 ft. (24.38m)

4

85 ft. (25.91m)

70 ft. (21.34m)

 

 

MAXIMUM LENGTH

 

of 4” (10.2cm) Semi-Rigid Metal Duct

Number

 

VENT HOOD TYPE

 

 

(Preferred)

 

of 90°

 

 

 

turns

 

 

2.5”

4”

 

 

(10.2cm)

louvered

(6.35cm)

0

60 ft. (18.29m)

45 ft. (13.72m)

1

50 ft. (15.24m)

35 ft. (10.67m)

2

40 ft. (12.19m)

25 ft. (7.62m)

3

 

NOT RECOMMENDED

 

Install male fittings in correct direction:

In installations where the exhaust system is not described in the charts, the following method must be used to determine if the exhaust system is acceptable:

CORRECTINCORRECT

Image 6
Contents Installation Instructions Please read and save this guide Table of contentsFinding Information Keep a record for quick referenceSafety Important Safety InstructionsPre-installation requirements Wire receptacle Nema type 14-30R Installation RequirementsWire receptacle Nema type 10-30R Electrical system requirementsGas supply requirements Exhaust system requirementsInstall male fittings in correct direction Manufactured or mobile home installation Exhaust directionDo not Install Your Dryer Clearance requirementsInstalled dryer dimensions Installation Instructions Electrical installationGrounding requirements Electric dryer USA Grounding requirements Electric dryer Canada Grounding requirements Gas dryer USA and CanadaElectrical connection non-Canada 3 wire cord Electrical connection non-Canada 4 wire cord Gas connection TodryerWater connection Steam Model only Water connection, con’t Steam Model only General installation Performing Installation Cycle Removing door and hardware Reversing DoorPreparing to reverse door swing Removing Trim RingReversing door Reversing Hardware on Front Panel Removing Door HardwareRemoving Latch Indicator Removing Hole Plug Reinserting Latch Indicator Reinserting Hole PlugReattaching Latch Plate Reattaching HingeReattaching Door to Front Panel Reversing Trim Ring Reinstalling Trim RingReinstalling Trim Plug Plug in dryer and continue operationReplacement parts 1-877-4ELECTROLUX OptionsAccesories