Electrolux EWMED65H, 137018200 A, 134912700, 134709300 Electrical connection non-Canada 3 wire cord

Page 12

12Installation Instructions

Electrical connection (non-Canada) - 3 wire cord

3-wire receptacle

(NEMA type 10-30R)

WARNING

ELECTRICAL SHOCK HAZARD

Failure to disconnect power source before servicing could result in personal injury or even death.

1.Turn off power supply to outlet.

2.Remove the screw securing the terminal block access cover in the lower corner on the back of the dryer.

3.Install a UL-approved strain relief according to the power cord/strain relief manufacturer’s instructions in the power cord entry hole below the access panel. At this time, the strain relief should be loosely in place.

4.Thread an UNPLUGGED, UL-approved, 30 amp. power cord, NEMA 10-30 type SRDT, through the strain relief.

5.Attach the power cord neutral (center wire) conductor to the SILVER colored center terminal on the terminal block. Tighten the screw securely.

6.Attach the remaining two power cord outer conductors to the outer, BRASS colored terminals on the terminal block. Tighten both screws securely.

WARNING

ELECTRICAL SHOCK HAZARD

Do not make a sharp bend or crimp wiring/ conductor at connections.

7.Follow manufacturer’s guidelines for firmly securing the strain relief and power cord.

8.Reinstall the terminal block cover.

IMPORTANT

If moving dryer from a 4-wire system and installing it in a 3-wire system, move the internal ground from the center terminal back to the GREEN screw next to the terminal block.

30 AMP

NEMA 10-30Neutral (center wire)

Access cover

screw

Terminal

block

Line 2

(BRASS terminal)

Neutral

(SILVER terminal)

Line 1

(BRASS terminal)

Internal ground (GREEN screw)

Install

UL-approved

strain relief here

Terminal screw

recovery slot

NOTE

If a terminal screw falls during cord installation, it can be retrieved in the terminal screw recovery slot below the access panel.

DO NOT remove

Neutral

internal ground in

terminal

a 3-wire system!!

 

Image 12
Contents Installation Instructions Table of contents Finding InformationPlease read and save this guide Keep a record for quick referenceSafety Important Safety InstructionsPre-installation requirements Installation Requirements Wire receptacle Nema type 10-30RWire receptacle Nema type 14-30R Electrical system requirementsGas supply requirements Exhaust system requirementsInstall male fittings in correct direction Manufactured or mobile home installation Exhaust directionDo not Install Your Dryer Clearance requirements Installed dryer dimensions Installation Instructions Electrical installationGrounding requirements Electric dryer USA Grounding requirements Electric dryer Canada Grounding requirements Gas dryer USA and CanadaElectrical connection non-Canada 3 wire cord Electrical connection non-Canada 4 wire cord Gas connection TodryerWater connection Steam Model only Water connection, con’t Steam Model only General installation Performing Installation Cycle Reversing Door Preparing to reverse door swingRemoving door and hardware Removing Trim RingReversing door Reversing Hardware on Front Panel Removing Door HardwareRemoving Latch Indicator Removing Hole Plug Reinserting Latch Indicator Reinserting Hole PlugReattaching Latch Plate Reattaching HingeReattaching Door to Front Panel Reinstalling Trim Ring Reinstalling Trim PlugReversing Trim Ring Plug in dryer and continue operationReplacement parts 1-877-4ELECTROLUX OptionsAccesories