Indicator | Name | Description |
|
|
|
|
| preprogrammed by the operator. |
|
|
|
| Proportional Band | This setting controls the amount in which the |
| Mode (P) | manipulated variable (MV) is proportionate to the |
|
| deviated value or controller error. |
|
|
|
| Integral Time | Setting this feature, gives the control an action that |
| Mode (I) | is proportionate to the time integral of the control |
|
| error. By using this setting, proportional action is |
|
| used in combination with integral action to offset |
|
| the control error and the set point will begin to |
|
| match the control temperature (PV or process |
|
| value). |
|
|
|
| Derivative Time | Setting the derivative control provides the |
| Mode (d) | controller with the ability to correct for a future |
|
| error in the previously set process output. |
|
|
|
Entering Operating Parameters to Select Modes
To enter the display:
1.Press the Mode Display key to view the Run/Stop & Alarm 1 Modes.
2.Press and to set the higher or lower the values of the parameter or turn that function On or Off.
The SV readout displays the different values for the parameter within a mode.
3.To switch modes within a level, press and hold the Level Display key for one
(1) second.
The PV readout will display the different parameters within each mode.
4.Use short presses on the Mode Display key to display each parameter within a mode.
The SV readout displays the different values for the parameter within a mode.
5.Press and to set the higher or lower the values of a parameter or turn that function On or Off.
6.Press Level Key once to return to the Process Temperature Setting.
15, 30, & 60 cfm Compact Dryers | 24 |