To Replace Gas Valve (Refer to burner illustration on page 14)
1.Discontinue electrical power to the dryer.
2.Close
3.Disconnect gas valve wiring.
NOTE: Identify location of each wire for correct reinstallation.
4.Break union connection before gas valve.
5.Loosen and remove four (4) screws securing pipe brackets to burner.
6.Remove valve and manifold assembly from dryer.
7.Remove valve mounting bracket, manifold and piping from gas valve.
8.Reverse procedure for installing new gas valve.
WARNING: Test ALLconnections for leaks by brushing on a soapy water solution.
WARNING: NEVER TEST FOR LEAKS WITHA FLAME!!!
To Replace Main Burner Orifices
1.Refer to “To Replace Gas Valve” above and follow Step #1 through Step #6.
2.Unscrew main burner orifices and replace.
NOTE: Use extreme care when removing and replacing orifices. These orifices are made of brass and are easily damaged.
3. Reverse the removal procedure for reinstalling.
NOTE: Test ALL connections for leaks by brushing on a soapy water solution.
WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!
To Test and Adjust Gas (Water Column) Pressure
There are two (2) types of devices commonly used to measure column pressure. They are spring and mechanical- type gauges and manometers. The spring and
NOTE: Manometers are available from the factory by ordering ADC P/N 122804.
19